Abbonarsi

Anteroposterior Versus Anterolateral Electrode Position for Direct Current Cardioversion of Atrial Fibrillation: A Meta-Analysis of Randomised Controlled Trials - 20/12/22

Doi : 10.1016/j.hlc.2022.08.016 
Sohaib A. Virk, BMed/MD a, Imants Rubenis, BMed/MD a, David Brieger, MBBS, PhD a, Hariharan Raju, MBChB, PhD a, b,
a Department of Cardiology, Concord Repatriation General Hospital, Sydney, NSW, Australia 
b Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, NSW, Australia 

Corresponding author at: Concord Repatriation General Hospital, Level 3 West, Department of Cardiology, Hospital Road, Concord, NSW 2139Concord Repatriation General HospitalDepartment of CardiologyHospital RoadLevel 3 WestConcordNSW2139

Abstract

Objective

Data regarding optimal electrode positioning for direct current cardioversion (DCCV) of atrial fibrillation (AF) has been inconsistent. This meta-analysis was conducted to systematically compare the efficacy of anteroposterior (AP) versus anterolateral (AL) electrode placement for DCCV of AF.

Methods

Electronic databases were searched for randomised controlled trials (RCTs) comparing AP versus AL electrode positioning in patients undergoing DCCV for AF. Primary endpoints were first-shock success and overall DCCV success. Subgroup analysis was performed by defibrillator waveform (monophasic versus biphasic). Meta-regression analyses were performed to assess for significant moderators.

Results

Twelve (12) RCTs, including a total of 2,046 patients, met inclusion criteria. Neither first-shock success (relative risk [RR] 0.92; 95% CI 0.79–1.07; p=0.28) nor overall DCCV success (RR 1.01; 95% CI 0.96–1.05; p=0.78) were significantly different with AP versus AL electrode positioning. The mean number of shocks (mean difference [MD] 0.3, 95% CI -0.4 to 0.9), energy level of first successful shock (MD 3 joules; 95% CI -20 to 27) and cumulative energy delivered (MD 39 joules; 95% CI -168 to 246) were similar in AP versus AL arms. In subgroup analysis of six RCTs using biphasic defibrillators, improvement in first-shock success (RR 0.85; 95% CI 0.69–1.03; p=0.10) and overall DCCV success (RR 0.97; 95% CI 0.93–1.01; p=0.09) with AL electrode positioning did not reach statistical significance. Meta-regression analyses identified older age, higher body mass index, and longer AF duration as significant moderators favouring AL electrode positioning.

Conclusions

Pooled analysis of randomised data overall does not show a significant difference in efficacy between AP versus AL electrode positioning. Meta-regression and subgroup analyses suggest that, in contemporary practice with use of biphasic defibrillators, there may be a subset of AF patients in whom AL electrode positioning improves efficacy of DCCV.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Atrial fibrillation, Direct current cardioversion, Electrode position, Meta-analysis


Mappa


© 2022  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 31 - N° 12

P. 1640-1648 - dicembre 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Long-Term Ambulatory Intravenous Milrinone Therapy in Advanced Heart Failure
  • Sandipan Shringi, Shiksha Joshi, John M. Suffredini, Ashley Schenk, Navin Rajagopalan, Maya Guglin
| Articolo seguente Articolo seguente
  • Ten Years of Percutaneous Pulmonary Valve Implantation in Australia and New Zealand
  • Claire M. Lawley, David Tanous, Clare O’Donnell, Benjamin Anderson, Nicholas Aroney, Darren L. Walters, Stephen Shipton, William Wilson, David S. Celermajer, Philip Roberts

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.