Abbonarsi

Does a Change in Device Design Alter Device Size Selection? A Comparison of Conventional and Occlutech Duct Occluder Designs - 20/12/22

Doi : 10.1016/j.hlc.2022.07.007 
Anand Subramanian, DM , Bharath A. Paraswanath, MD, FNB,  Govind Auradkar, MD, Jayranganath Mahimarangaiah, DM
 Paediatric Cardiology, Sri Jayadeva Institute of Cardiovascular Sciences & Research, Bangalore, India 

Corresponding author at: Department of Pediatric Cardiology, Sri Jayadeva Institute of Cardiovascular Sciences & Research, Bannerghatta Road, Bangalore, India – 560069.Department of Pediatric CardiologySri Jayadeva Institute of Cardiovascular Sciences & ResearchBannerghatta roadBangalore560069India

Abstract

Aim

The Occlutech duct occluder (ODO) with a novel design has been available for closure of patent ductus arteriosus (PDA) since 2011. Available data on initial experience with the ODO have shown that operators continue to choose device sizes based on their experience with conventional duct occluders (CDO). This study postulated that occlusion of the pulmonary arterial (PA) end of the ductus should achieve satisfactory PDA closure without additional complications. Accordingly, the size of the ODO was chosen such that the larger PA diameter in the new design exceeded the PA end of the ductus by 2–3 mm and 2–4 mm for normotensive and hypertensive ducts, respectively. It sought to examine the feasibility and safety of such an approach, and compared ODO and CDO devices with respect to device sizes deployed, to ascertain if the newer design had any advantages.

Methods

This prospective study enrolled 105 infants, children and a few adults with various duct morphologies and PA pressures for ductal closure using the ODO from 2018–2020. The control group consisted of 105 ducts closed with CDO. A comparison of the two groups with respect to duct diameter and implanted device sizes was performed using appropriate statistical software.

Results

The study found that 40% of the ducts had moderate-to-severe pulmonary hypertension. Most ducts measured between 3–4 mm in both groups. The mean weight of the subjects in both groups was 12 kg. Although there was no change in the way that duct occluders were chosen in both groups (2–3 mm over the pulmonary artery diameter), ODO could be significantly downsized in most ducts measuring between 2.5–6.4 mm in diameter (p<0.05).

Conclusions

This study found successful closure of relatively larger PDA in infants and children using smaller ODO compared with CDO, without embolisation or aortic narrowing. It also demonstrated that a different device size selection technique may be safely employed with the ODO.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Patent ductus arteriosus, Occlutech, Duct occluder, Conventional design, Size selection


Mappa


© 2022  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 31 - N° 12

P. 1677-1684 - dicembre 2022 Ritorno al numero
Articolo precedente Articolo precedente
  • Efficacy of Off-Pump Coronary Artery Bypass Grafting With Concomitant Transcatheter Aortic Valve Replacement
  • Yusuke Shimahara, Satsuki Fukushima, Hideaki Kanzaki, Yasuhide Asaumi, Makoto Amaki, Naonori Kawamoto, Satoshi Kainuma, Naoki Tadokoro, Takashi Kakuta, Kensuke Takagi, Michikazu Nakai, Junjiro Kobayashi, Tomoyuki Fujita
| Articolo seguente Articolo seguente
  • Outcomes of Cardiac Transplantation in Western Australia – A Contemporary Single Centre Experience
  • Umar Ali, Lauren Giudicatti, Felicity Lee, Clare Fazackerley, Karim Slimani, Chris Merry, Amit Shah, Robert Larbalestier

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.