Aerosol containment device design considerations and performance evaluation metrics - 13/01/23

Doi : 10.1016/j.ajem.2022.11.007 
Rachael M. Jones, PhD a, b, , Niles Andrus, MS a, Thomas Dominguez, MS a, Jeremy Biggs, MD a, Brian Hansen, MS a, Frank A. Drews, PhD c
a Department of Family and Preventive Medicine, Spencer Fox Eccles School of Medicine, University of Utah, United States of America 
b Department of Environmental Health Sciences, Fielding School of Public Health, University of California, Los Angeles, United States of America 
c Department of Psychology, College of Social and Behavioral Science, University of Utah, United States of America 

Corresponding author at: 650 Charles E Young Dr. S, 71-295, Center for Health Sciences, Los Angeles, CA 90095, United States of America.Center for Health Sciences650 Charles E Young Dr. S, 71-295Los AngelesCA90095United States of America

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

Spurred by the Coronavirus infectious disease 2019 pandemic, aerosol containment devices (ACDs) were developed to capture infectious respiratory aerosols generated by patients at their source. Prior reviews indicated that such devices had low evidence of effectiveness, but did not address how ACDs should be evaluated, how well they should perform, nor have clearly defined performance standards. Towards developing design criteria for ACDs, two questions were posed: 1) What characteristics have guided the design of ACDs? 2) How have these characteristics been evaluated?

Methods

A scoping review was performed consistent with PRISMA guidelines. Data were extracted with respect to general study information, intended use of the device, device design characteristics and evaluation.

Results

Fifty-four articles were included. Evaluation was most commonly performed with respect to device aerosol containment (n = 31, 61%), with only 5 (9%), 3 (6%) and 8 (15%) formally assessing providing experience, patient experience and procedure impact, respectively. Nearly all of the studies that explored provider experience and procedure impact studied intubation. Few studies provided a priori performance criteria for any evaluation metric, or referenced any external guidelines by which to bench mark performance.

Conclusion

With respect to aerosol containment, ACDs should reduce exposure among HCP with the device compared with the absence of the device, and provide ≥90% reduction in respirable aerosols, equivalent in performance to N95 filtering facepiece respirators, if the goal is to reduce reliance on personal protective equipment. The ACD should not increase awkward or uncomfortable postures, or adversely impact biomechanics of the procedure itself as this could have implications for procedure outcomes. A variety of standardized instruments exist to assess the experience of patients and healthcare personnel. Integration of ACDs into routine clinical practice requires rigorous studies of aerosol containment and the user experience.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Aerosol box, COVID−19, Engineering controls, Respiratory aerosols

Abbreviations : ACD, AIIR, APF, COVID-19, D, FD, FFR, HCP, M, NASA TLX, PRISMA, R, SARS-CoV-2


Mappa


© 2022  The Authors. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 64

P. 12-20 - febbraio 2023 Ritorno al numero
Articolo precedente Articolo precedente
  • Recent developments and controversies in therapeutic hypothermia after cardiopulmonary resuscitation
  • Peijuan Li, Zhangping Sun, Tian Tian, Dongping Yu, Hui Tian, Ping Gong
| Articolo seguente Articolo seguente
  • Continuous compression with asynchronous ventilation improves CPR prognosis? A meta-analysis from human and animal studies
  • Mengxue Sun, Aiqun Zhu, Yangyang Tang

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.