Abbonarsi

Aerosol Generation During High Intensity Exercise—Implications for COVID-19 Transmission - 02/02/23

Doi : 10.1016/j.hlc.2022.10.014 
Brian Cowie, MBBS, FANZCA a, b, , Imogen Wadlow, BSc c, d, Andrew Yule, MSc e, Kristel Janssens, MSc a, i, Jason Ward, BSc d, Steve Foulkes, PhD a, i, Ruhi Humphries, PhD d, Forbes McGain, PhD f, g, Rana Dhillon, MBBS, FRACS h, André La Gerche, PhD a, i, j
a Sports Cardiology Laboratory, Baker Heart and Diabetes Institute, Melbourne, Vic, Australia 
b Department of Anaesthesia, St Vincent’s Hospital, Melbourne, Vic, Australia 
c Department of Atmospheric Science, University of Melbourne, Melbourne, Vic, Australia 
d Climate Science Centre, CSIRO Oceans and Atmosphere, Melbourne, Vic, Australia 
e Australian Radiation Protection and Nuclear Safety Agency, Melbourne, Vic, Australia 
f Department of Anaesthesia and Intensive Care, Western Health, Vic, Australia 
g Department of Critical Care, University of Melbourne, Melbourne, Vic, Australia 
h Department of Neurosurgery, St. Vincent’s Hospital, Melbourne, Vic, Australia 
i Department of Cardiometabolic Health, University of Melbourne, Melbourne, Vic, Australia 
j National Centre for Sports Cardiology, St Vincent’s Hospital Melbourne, Melbourne, Vic, Australia 

Corresponding author at: Dr Brian Cowie, Department of Anaesthesia, St. Vincent’s Hospital, Melbourne, Vic, AustraliaDepartment of AnaesthesiaSt. Vincent’s HospitalMelbourneVicAustralia

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background and Aim

COVID-19 can be transmitted through aerosolised respiratory particles. The degree to which exercise enhances aerosol production has not been previously assessed. We aimed to quantify the size and concentration of aerosol particles and evaluate the impact of physical distance and surgical mask wearing during high intensity exercise (HIE).

Methods

Using a prospective observational crossover study, three healthy volunteers performed high intensity cardiopulmonary exercise testing at 80% of peak capacity in repeated 5-minute bouts on a cycle ergometer. Aerosol size and concentration was measured at 35, 150 and 300 cm from the participants in an anterior and lateral direction, with and without a surgical face mask, using an Aerodynamic Particle Sizer (APS) and a Mini Wide Range Aerosol Spectrometer (MiniWRAS), with over 10,000 sample points.

Results

High intensity exercise generates aerosol in the 0.2–1 micrometre range. Increasing distance from the rider reduces aerosol concentrations measured by both MiniWRAS (p=0.003 for interaction) and APS (p=0.041). However, aerosol concentrations remained significantly increased above baseline measures at 300 cm from the rider. A surgical face mask reduced submicron aerosol concentrations measured anteriorly to the rider (p=0.031 for interaction) but not when measured laterally (p=0.64 for interaction).

Conclusions

High intensity exercise is an aerosol generating activity. Significant concentrations of aerosol particles are measurable well beyond the commonly recommended 150 cm of physical distancing. A surgical face mask reduces aerosol concentration anteriorly but not laterally to an exercising individual. Measures for safer exercise should emphasise distance and airflow and not rely solely on mask wearing.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Coronavirus, COVID-19, Aerosol, Exercise, Sport, Indoor air quality


Mappa


 Trial registration - The project was registered with the Australian and New Zealand Clinical Trials Registry (ANZCTR) (Registration number ACTRN12621000130864).


© 2022  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 32 - N° 1

P. 67-78 - gennaio 2023 Ritorno al numero
Articolo precedente Articolo precedente
  • Short-Term Exposure to Sulfur Dioxide and Nitrogen Monoxide and Risk of Out-of-Hospital Cardiac Arrest
  • Bing Zhao, Fay H. Johnston, Farhad Salimi, Kiyohiro Oshima, Masahiko Kurabayashi, Kazuaki Negishi
| Articolo seguente Articolo seguente
  • Effects of Air Pollutant Exposure on Acute Myocardial Infarction
  • Maryam Mohammadian-Khoshnoud, Hossein Habibi, Babak Manafi, Gholamreza Safarpour, Ali Reza Soltanian

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.