Abbonarsi

Design of Adjustable Frame-Type Prosthetic Socket for Lower Limb - 04/02/23

Doi : 10.1016/j.irbm.2022.07.002 
M.H. Wang a, b, , Q.J. Nong a, b, Y. Qian a, b, Y.H. Huang a, b, Y.H. Wang a, b, H.L. Yu a, b
a Institute of Rehabilitation Engineering and Technology, School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China 
b Shanghai Engineering Research Center of Assistive Devices, Shanghai 200093, China 

Corresponding author at: School of Health Science and Engineering, University of Shanghai for Science and Technology, Jungong Road 516, Shanghai, 200093, China.School of Health Science and EngineeringUniversity of Shanghai for Science and TechnologyJungong Road 516Shanghai200093China

Abstract

Objectives

Prosthetic socket is the contact interface between the stump and the prosthesis, and also the interface component that transmits forces from the stump to the prosthesis distal. The current prosthetic socket fit is a major factor affecting rehabilitation, especially with the stump volume fluctuations. The main goal of this article is to design an adjustable frame-type prosthetic socket with constant force to adapt to the stump volume fluctuations.

Materials and methods

In this paper, an adjustable frame-type prosthetic socket with constant force is designed. The constant force device is designed based on the superelasticity of the shape memory alloy for maintaining constant stump-socket interface stress and automatically adapting to certain volume fluctuations. The constant force extrusion performance of this prosthetic socket was verified and optimized by finite element analysis.

Results

The results suggest that the constant force unit may maintain constant interface stress. According to the optimization results, the shape memory alloy dimensional parameters could be selected according to different requirements.

Conclusion

The adjustable frame-type prosthetic socket allows the user to adjust the socket volume through the cable system and has a large heat dissipation area. The constant force unit maintains constant interface stress and automatically adapts to stump volume fluctuations.

Il testo completo di questo articolo è disponibile in PDF.

Graphical abstract

Il testo completo di questo articolo è disponibile in PDF.

Highlights

Volume fluctuations cause interface pressure mismatch.
Constant force extrusion for stump may solve interface pressure mismatch.
An adjustable frame-type socket with constant force is designed.
Constant force extrusion of the prosthetic socket is verified by FEA.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Interface stress, Prosthetic socket, Shape memory alloy, Stump, Superelasticity, Volume fluctuation


Mappa


© 2022  AGBM. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 44 - N° 1

Articolo 100731- febbraio 2023 Ritorno al numero
Articolo precedente Articolo precedente
  • Automatic Detection of Severely and Mildly Infected COVID-19 Patients with Supervised Machine Learning Models
  • M.T. Huyut
| Articolo seguente Articolo seguente
  • CRISPR-OTE: Prediction of CRISPR On-Target Efficiency Based on Multi-Dimensional Feature Fusion
  • J. Xie, M. Liu, L. Zhou

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.