Abbonarsi

Single and double developing lines improve ultrasound-guided radial artery catheterization in obese patients: A randomized controlled trial - 22/03/23

Doi : 10.1016/j.accpm.2022.101166 
Qi Zou, Jindi Jiang, Chonglong Shi, Bianliang Wu, Bo Gui, Xuelong Zhou
 Department of Anesthesiology and Perioperative Medicine, The First Affiliated Hospital of Nanjing Medical University, Nanjing, China 

Corresponding author.

Abstract

Background

Arterial catheterization is challenging in obese patients. The present study tested the hypothesis that ultrasound guidance with acoustic shadowing improves the success rate of radial artery catheterization in obese patients.

Methods

240 obese patients were enrolled and were randomly assigned to three groups: control group, single developing line group, or double developing lines group. Patients underwent radial artery catheterization guided by acoustic shadowing ultrasound with none, single or double developing lines. The primary outcome was the first-attempt success rate. The secondary outcomes included the procedure time and complication rate.

Results

In the single or double developing lines group, the success rate of radial artery catheterization at the first attempt was higher than in the control group (control vs. single vs. double, 71% vs. 90% vs. 91%, P = 0.001). Besides, the single and double developing lines groups had a shorter procedure time to success at the first attempt and a lower overall complication (vasospasm and hematoma) rate than the control group (procedure time: control vs. single vs. double, 63 s vs. 54 s vs. 40 s, P < 0.001; overall complication rate: control vs. single vs. double, 29% vs. 10% vs. 9%, P = 0.001). There was no significant difference in the first-attempt success rate, the procedure time to success within the first attempt, or overall complications’ rate between the single and double developing lines groups.

Conclusion

Single and double developing lines improve first-attempt success rate and reduced the overall complications’ rate of ultrasound-guided radial artery catheterization in obese patients.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Arterial catheterization, Ultrasonography, Acoustic shadowing, Success rate, Complication rate


Mappa


© 2022  Société française d'anesthésie et de réanimation (Sfar). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 42 - N° 2

Articolo 101166- aprile 2023 Ritorno al numero
Articolo precedente Articolo precedente
  • Development, validation, and feature extraction of a deep learning model predicting in-hospital mortality using Japan’s largest national ICU database: a validation framework for transparent clinical Artificial Intelligence (cAI) development
  • Euma Ishii, Nobutoshi Nawa, Satoru Hashimoto, Hidenobu Shigemitsu, Takeo Fujiwara
| Articolo seguente Articolo seguente
  • Evaluation of nociception in unconscious critically ill patients using a multimodal approach
  • Sara Fratino, Annalisa Garré, Alessandra Garufi, Sofia Hafidi, Ernesto Migliorino, Serena Stropeni, Elisa Gouvea Bogossian, Narcisse Ndieugnou Djangang, Giovanni Albano, Jacques Creteur, Lorenzo Peluso, Fabio Silvio Taccone

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.