Abbonarsi

A novel new 3D volume echo derived method for regurgitation fraction quantification in isolated aortic regurgitation - 13/05/23

Doi : 10.1016/j.acvdsp.2023.04.023 
V. Baland , N. Pace, C. Selton Suty, A. Fraix, O. Huttin, D. Mandry, L. Filippetti
 CHRU Nancy, Nancy, France 

Corresponding author.

Riassunto

Introduction

Accurate quantification of chronic aortic regurgitation (AR) using 2D-TTE is sometimes challenging. Cardiac magnetic resonance imaging (CMR) is increasingly used to refine this assessment by estimating measurement of regurgitation fraction (RF), but remains not widely available. 3D echocardiography (3D-ETT) allows a non-invasive approach of right ventricular (RV) and left ventricular (LV) volumes with a good correlation with CMR measurements. The 3D-TTE volume method is based on the comparison of RV and LV stroke volumes, which is then used to calculate the RF of the aortic valve in isolated AR.The primary objective of this study was to investigate the ability of 3D-TTE to assess the severity of chronic AR based on the criterion of regurgitation fraction (RF) obtained by the volume method in comparison to PC-CMR.

Method

We enrolled 42 patients with isolated AR who underwent ASE algorithm-guided 2D echocardiography (2D-TTE), 3D echocardiography and CMR. Regurgitation fraction (RF) was calculated by 3D-TTE using the formula [(LV Stroke Volume–RV Stroke Volume)/LV Stroke Volume]×100. Correlation and concordance between 3D-TTE-RF and PC-CMR-RF were analyzed. Reproducibility of 3D-TTE-RF measurement was evaluated.

Results

Seven (17%) had mild AR, 27 (64%) moderate AR, and 8 (19%) severe AR in PC-CMR. Mean RF was 32.7±13.9% by 3D-TTE and 30,7±14,9% by PC-CMR-RF (P<0,05). 3D-TTE-RF and PC-CMR-RF had a good correlation (r=0.90, P<0,05). We found a good intra-operator (r:0.95, P<0.05) and inter-operator (r:0.87, P<0.05) reproductibility. The final gradation of AR was concordant between 3D TTE and PC-CMR in 88% of the cases.

Conclusion

The assessment of isolated aortic regurgitation fraction in 3D-TTE by the volumetric method is a feasible and reproducible method in daily clinical practice, with a good correlation to PC-CMR. Estimation of the aortic regurgitation fraction in (Figure 1).

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2023  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 15 - N° 3

P. 254-255 - giugno 2023 Ritorno al numero
Articolo precedente Articolo precedente
  • Multimodal imaging assessment of mitral valve area after transcatheter mitral valve implantation: A three-dimensional echocardiographic and CT scan study
  • M. Jullien, M. Urena, D. Himbert, C. Nguyen, E. Brochet, P. Ou, B. Iung
| Articolo seguente Articolo seguente
  • Impact of fibrosis extend on multiparametric assessment for ventricular arrhythmias risk in non-ischemic dilated cardiomyopathy
  • G. Chassard, L. Filippetti, N. Girerd, N. Hammache, N. Sadoul, O. Huttin, P.Y. Marie, I. Magnin Poull

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.