Abbonarsi

EUS-guided fine-needle biopsy sampling of solid pancreatic tumors with 3 versus 12 to-and-fro movements: a multicenter prospective randomized controlled study - 17/05/23

Doi : 10.1016/j.gie.2023.01.037 
Kosuke Takahashi, MD, PhD 1, 2, Ichiro Yasuda, MD, PhD 1, , Nobuhiko Hayashi, MD, PhD 1, Takuji Iwashita, MD, PhD 3, Mitsuru Okuno, MD, PhD 4, Tsuyoshi Mukai, MD, PhD 4, 5, Masatoshi Mabuchi, MD, PhD 6, Seiji Adachi, MD, PhD 6, Shinpei Doi, MD, PhD 7, Johji Imura, MD, PhD 8, Eisuke Ozawa, MD, PhD 2, Hisamitsu Miyaaki, MD, PhD 2, Kazuhiko Nakao, MD, PhD 2
1 Third Department of Internal Medicine, University of Toyama, Toyama, Japan 
8 Department of Diagnostic Pathology, Faculty of Medicine, Academic Assembly, University of Toyama, Toyama, Japan 
2 Department of Gastroenterology and Hepatology, Graduate School of Biomedical Sciences, Nagasaki University, Nagasaki, Japan 
3 First Department of Internal Medicine, Gifu University Hospital, Gifu, Japan 
4 Department of Gastroenterology, Gifu Municipal Hospital, Gifu, Japan 
5 Department of Gastroenterological Endoscopy, Kanazawa Medical University, Ishikawa, Japan 
6 Department of Gastroenterology, Gihoku Kousei Hospital, Gifu, Japan 
7 Department of Gastroenterology, Teikyo University Mizonokuchi Hospital, Kanagawa, Japan 

Reprint requests: Ichiro Yasuda, MD, PhD, Third Department of Internal Medicine, University of Toyama, 2630 Sugitani, Toyama 930-0194, Japan. Third Department of Internal Medicine University of Toyama 2630 Sugitani Toyama 930-0194 Japan

Abstract

Background and Aims

A novel EUS-guided fine-needle biopsy sampling (EUS-FNB) needle enabled physicians to obtain sufficient pathologic samples with fewer to-and-fro movements (TAFs) within the lesion. We compared the diagnostic yields of EUS-FNB with 3 and 12 TAFs at each puncture pass.

Methods

The primary endpoint of this multicenter, noninferiority, crossover, randomized controlled trial involving 6 centers was diagnostic sensitivity. Secondary endpoints were diagnostic accuracy and quantity and quality evaluation of EUS-FNB specimens. Length of the macroscopically visible core (MVC) and microscopic histologic quantity were used for quantitative evaluation. Macroscopic visual and microscopic histologic evaluations were performed for qualitative evaluation.

Results

Among 110 patients (220 punctures, 110 for 3 TAFs and 12 TAFs each), 105 (210 punctures) had malignant histology. Diagnostic sensitivity for malignancy of 3 TAFs (88.6%) was not inferior to that of 12 TAFs (89.5%; difference, –.9%; 95% confidence interval, –9.81 to 7.86). Diagnostic accuracy for malignancy was 92.7% for 3 TAFs and 94.6% for 12 TAFs. Overall median MVC length was 13.5 mm in both groups. The 3-TAF group had a significantly higher rate of score ≥3 on macroscopic visual quality evaluation than the 12-TAF group (71.8% vs 52.7%, P  = .009). No significant intergroup differences existed in microscopic histologic quantity and quality evaluations (quantity evaluation, 88.2% for 3 TAFs vs 83.6% for 12 TAFs; quality evaluation, 90.0% for 3 TAFs vs 89.1% for 12 TAFs).

Conclusions

Diagnostic sensitivity and accuracy of EUS-FNB with 3 TAFs were not inferior to those with 12 TAFs for solid pancreatic lesions. The 3-TAF group showed significantly less blood contamination in sampled tissues than the 12-TAF group. (Clinical trial registration number: UMIN000037309.)

Il testo completo di questo articolo è disponibile in PDF.

Graphical abstract




Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : CI, EUS-FNA, EUS-FNB, MOSE, MVC, TAF, TUH


Mappa


  DISCLOSURE: All authors disclosed no financial relationships.


© 2023  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 97 - N° 6

P. 1092-1099 - giugno 2023 Ritorno al numero
Articolo precedente Articolo precedente
  • Investigation into the content of red material in EUS-guided pancreatic cancer biopsies
  • Meng-Ying Lin, Yung-Yeh Su, Yu-Ting Yu, Chien-Jui Huang, Bor-Shyang Sheu, Wei-Lun Chang
| Articolo seguente Articolo seguente
  • Cold snare EMR for the removal of large duodenal adenomas
  • Hunter Wang, Mayenaaz Sidhu, Sunil Gupta, Oliver Cronin, Timothy O’Sullivan, Anthony Whitfield, Nicholas G. Burgess, Michael J. Bourke

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.