Abbonarsi

Opioid Overdose Detection in a Murine Model Using a Custom-Designed Photoplethysmography Device - 14/09/23

Doi : 10.1016/j.irbm.2023.100792 
Orlando S. Hoilett a, 1, Jason D. Ummel a, 1, Luke E. Schepers a, Arvin H. Soepriatna a, Jessica L. Ma a, Akio K. Fujita b, Alyson S. Pickering c, Benjamin D. Walters a, Craig J. Goergen a, Jacqueline C. Linnes a,
a Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907, USA 
b The Elmore Family School of Electrical and Computer Engineering, Purdue University, West Lafayette, IN 47907, USA 
c School of Materials Engineering, Purdue University, West Lafayette, IN 47907, USA 

Corresponding author at: 206 S. Martin Jischke Drive, West Lafayette, IN 47907.206 S. Martin Jischke DriveWest LafayetteIN47907

Abstract

Background and Objective

Over 68,000 opioid-overdose related deaths occurred within the United States in 2020 alone, indicating a need to develop technologies to help curb this growing epidemic. The ability to detect respiratory rate (RR) depression in real-time has the potential to decrease adverse outcomes by alerting emergency medical services or willing bystanders to an overdose event. The aim of this investigation was to design, build, and test a novel photoplethysmography (PPG)-based measurement device capable of monitoring RR and identifying respiratory depression.

Materials and Methods

We developed a novel murine model for opioid-induced respiratory depression (OIRD) to demonstrate the PPG device's capabilities. We induced respiratory depression in mice using both isoflurane and opioid-overdose and initiated recovery events with injections of naloxone while monitoring respiration via PPG and a laboratory reference system.

Results and Discussion

The device accurately identified all anesthesia-induced respiratory depression (n = 5) and OIRD events (n = 3). Our PPG-based monitor showed significant correlation with a reference respiratory measurement system ( ). The bias measured across the isoflurane trials was 0.6 breaths per minute (BrPM), while the bias measured across the oxycodone trials was −1.0 BrPM, with mean absolute errors of 1.5 and 3.6 BrPM, respectively, indicating that our device was able to accurately measure RR in a murine model.

Conclusions

These preliminary experiments suggest that our device could detect OIRD and could potentially be adaptable to humans with modifications to firmware and more extensive validation in human subjects. Our present study is a proof-of-concept for detecting OIRD and alerting bystanders and health professionals in real-time.

Il testo completo di questo articolo è disponibile in PDF.

Graphical abstract

Il testo completo di questo articolo è disponibile in PDF.

Highlights

Photoplethysmography device for measuring respiratory rate in murine model.
Able to detect opioid-induced respiratory rate depression in murine model.
Open-source software libraries for signal analysis on an embedded platform.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2023  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 44 - N° 5

Articolo 100792- ottobre 2023 Ritorno al numero
Articolo precedente Articolo precedente
  • A Control Strategy for Pneumatically Powered Below-Hip Orthosis
  • M Ashmi, VM Akhil
| Articolo seguente Articolo seguente
  • Classification of Moderate and Advanced Alzheimer's Patients Using Radial Basis Function Based Neural Networks Initialized with Fuzzy Logic
  • Carlos Roncero Parra, Alfonso Parreño Torres, Jorge Mateo Sotos, Alejandro L. Borja

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.