Abbonarsi

Percutaneous hallux valgus surgery: Anatomical study of its safety and effectiveness - 29/11/23

Doi : 10.1016/j.otsr.2022.103266 
Ester Navarro-Cano a, b, , Ana Carrera b, Marko Konschake c, Kerbi Alejandro Guevara-Noriega d, Francisco Reina b
a Orthopaedic Surgery Department, Sant Celoni Hospital, Sant Celoni, Spain 
b Department of Medical Sciences, Research Group on Clinical Anatomy, Embryology and Neuroscience (NEOMA), Faculty of Medicine, University of Girona, 77 Emili Grahit St, 17003, Girona, Spain 
c Institute of Clinical and Functional Anatomy, Medical University of Innsbruck, Innsbruck, Austria 
d Vascular Surgery Department, Parc Taulí University Hospital, Sabadell, Spain 

Corresponding author at: Department of Medical Sciences, Research Group on Clinical Anatomy, Embryology and Neuroscience (NEOMA), Faculty of Medicine, University of Girona, 77 Emili Grahit St, Girona 17003, Spain.Department of Medical Sciences, Research Group on Clinical Anatomy, Embryology and Neuroscience (NEOMA), Faculty of Medicine, University of Girona77 Emili Grahit StGirona17003Spain

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background and hypothesis

Although percutaneous hallux valgus surgery is increasing in popularity, concerns about safety regarding neurovascular and tendinous structures remain. The first aim of this body-donor study was to evaluate the safety of three common percutaneous portals. Secondly, to evaluate percutaneous surgery effectiveness in completing adductor tendon release and first ray osteotomies.

Patients and methods

Twenty body-donor feet were included and underwent three percutaneous procedures, which are commonly performed in combination: distal metatarsal osteotomy, proximal phalanx osteotomy and adductor tendon release. After surgery, the distance between surgical portals and relevant neurovascular structures was measured. Damage to this neurovascular structures, tendons or articular cartilage was noted. Completion of adductor tendon release and osteotomies was verified.

Results

The medial dorsal digital nerve of the hallux was damaged in two specimens. Mild peritendon damage was observed in two feet. The rest of neurovascular and tendinous structures were intact. No cartilage damage was observed. The distance between the adductor tenotomy portal and the lateral dorsal digital nerve of the hallux and the first dorsal metatarsal artery was 3.3mm (SD 1.4) and 2.4mm (SD 1.8), respectively. Complete adductor tenotomy was achieved in 14 feet.

Conclusions

The structure with the highest risk of damage during percutaneous hallux valgus surgery is the medial dorsal digital nerve. The lateral dorsal digital nerve and the first dorsal metatarsal artery might be at risk due to the small distance to the adductor tendon release portal. A deep anatomical knowledge and a meticulous surgical technique are required to avoid lesions to neurovascular and tendinous structures.

Level of evidence

V, Cadaveric study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Hallux valgus, Percutaneous surgery, Minimally Invasive, Foot Surgery


Mappa


© 2022  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 109 - N° 8

Articolo 103266- dicembre 2023 Ritorno al numero
Articolo precedente Articolo precedente
  • Endoscopic flexor hallucis longus tendon transfer with horizontal calcaneal fixation and suturing onto itself
  • Alexis Thiounn, Pierre Auzias, Alexandre Hardy
| Articolo seguente Articolo seguente
  • Prospective observational analysis of intraoperative radiation exposure with a mini C-arm intensifier in percutaneous forefoot surgery
  • Tristan Duguay, Victor Housset, Pierre Alban Bouché, Alexandre Hardy, Thomas Bauer

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.