Abbonarsi

Development of convolutional neural network models that recognize normal anatomic structures during real-time radial-array and linear-array EUS (with videos) - 16/01/24

Doi : 10.1016/j.gie.2023.10.028 
Carlos Robles-Medranda, MD, FASGE, AGAF 1, , Jorge Baquerizo-Burgos, MD 1, Miguel Puga-Tejada, MD, PhD 1, Raquel Del Valle, MD 1, Juan C. Mendez, ENG 2, Maria Egas-Izquierdo, MD 1, Martha Arevalo-Mora, MD 1, Domenica Cunto, MD 1, Juan Alcívar-Vasquez, MD, MSc 1, Hannah Pitanga-Lukashok, MD 1, Daniela Tabacelia, MD 3, 4
1 Gastroenterology and Endoscopy Division, Instituto Ecuatoriano de Enfermedades Digestivas, Guayaquil, Ecuador 
2 Research and Development Department, mdconsgroup, Guayaquil, Ecuador 
3 Gastroenterology and Hepatology, Elias Emergency University Hospital, Bucharest, Romania 
4 Faculty of Medicine, Carol Davila University of Medicine and Pharmacy, Bucharest, Romania 

Reprint requests: Carlos Robles-Medranda, MD, Endoscopy Division, Instituto Ecuatoriano de Enfermedades Digestivas, Av. Abel Romero Castillo S/N y Av. Juan Tanca Marengo, Torre Vitalis I, Mezzanine 3, Guayaquil, Ecuador 090505.Endoscopy DivisionInstituto Ecuatoriano de Enfermedades DigestivasAv. Abel Romero Castillo S/N y Av. Juan Tanca MarengoTorre Vitalis IMezzanine 3Guayaquil090505Ecuador

Abstract

Background and Aims

EUS is a high-skill technique that requires numerous procedures to achieve competence. However, training facilities are limited worldwide. Convolutional neural network (CNN) models have been previously implemented for object detection. We developed 2 EUS-based CNN models for normal anatomic structure recognition during real-time linear- and radial-array EUS evaluations.

Methods

The study was performed from February 2020 to June 2022. Consecutive patient videos of linear- and radial-array EUS videos were recorded. Expert endosonographers identified and labeled 20 normal anatomic structures within the videos for training and validation of the CNN models. Initial CNN models (CNNv1) were developed from 45 videos and the improved models (CNNv2) from an additional 102 videos. CNN model performance was compared with that of 2 expert endosonographers.

Results

CNNv1 used 45,034 linear-array EUS frames and 21,063 radial-array EUS frames. CNNv2 used 148,980 linear-array EUS frames and 128,871 radial-array EUS frames. Linear-array CNNv1 and radial-array CNNv1 achieved a 75.65% and 71.36% mean average precision (mAP) with a total loss of .19 and .18, respectively. Linear-array CNNv2 obtained an 88.7% mAP with a .06 total loss, whereas radial-array CNNv2 achieved an 83.5% mAP with a .07 total loss. CNNv2 accurately detected all studied normal anatomic structures with a >98% observed agreement during clinical validation.

Conclusions

The proposed CNN models accurately recognize the normal anatomic structures in prerecorded videos and real-time EUS. Prospective trials are needed to evaluate the impact of these models on the learning curves of EUS trainees.

Il testo completo di questo articolo è disponibile in PDF.

Graphical abstract




Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : AI, CNN, CNNv1, CNNv2, CNNv1-L, CNNv2-L, CNNv1-R, CNNv2-R, DL, FPS, mAP, NPV, PPV


Mappa


© 2024  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 2

P. 271 - febbraio 2024 Ritorno al numero
Articolo precedente Articolo precedente
  • Novel powered 5.0-mm endoscopic debridement catheter for endoscopic transmural necrosectomy of pancreatic walled-off necrosis: a case series of consecutive patients from a tertiary referral center (with video)
  • Gitte Aabye Olsen, Palle Nordblad Schmidt, Srdan Novovic, Erik Feldager Hansen, John Gásdal Karstensen
| Articolo seguente Articolo seguente
  • A case of rare early type 0-IIb esophageal adenoid cystic carcinoma accompanied by squamous cell carcinoma
  • Lianjun Di, Xinglong Wu, Biguang Tuo

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.