Abbonarsi

Analyzing methods for reducing recurrence rates after EMR of large nonpedunculated colorectal polyps: an indirect pairwise comparison - 15/02/24

Doi : 10.1016/j.gie.2023.11.060 
Dhruvil Radadiya, MD 1, , Madhav Desai, MD, MPH 2, Harsh Patel, MD 1, Sachin Srinivasan, MD 1, Viveksandeep Thoguluva Chandrasekar, MD 3, Cesare Hassan, MD 4, Alessandro Repici, MD 4, Douglas Rex, MD 5, Prateek Sharma, MD 1, 6
1 Division of Gastroenterology, Department of Internal Medicine, University of Kansas–School of Medicine, Kansas City, Kansas, USA 
2 Division of Gastroenterology hepatology and nutrition, Department of Medicine, University of Minnesota Medical Center, Minneapolis, Minnesota, USA 
3 Division of Gastroenterology, Department of Internal Medicine, Augusta University, Augusta, Georgia, USA 
4 Endoscopy Unit, IRCCS Humanitas Clinical and Research Center, Rozzano, Italy 
5 Division of Gastroenterology, Indiana University School of Medicine, Indianapolis, Indiana, USA 
6 Kansas City VA Medical Center, Kansas City, Missouri, USA 

Reprint requests: Dhruvil Radadiya, MD, Division of Gastroenterology, Hepatology, and Motility, University of Kansas, 3901 Rainbow Blvd #MS 1023, Kansas City, KS 66160.Division of GastroenterologyHepatologyand MotilityUniversity of Kansas3901 Rainbow Blvd #MS 1023Kansas CityKS66160

Abstract

Background and aims

Despite advances in EMR techniques, a high polyp recurrence rate remains a challenge. Due to the scarcity of direct comparisons, we performed an indirect comparison of conventional EMR (EMR alone), underwater EMR (U-EMR), and EMR + adjuvant thermal ablation of polypectomy margins to assess polyp recurrence rates.

Methods

Electronic databases were searched from inception to January 12, 2023, for studies reporting polyp recurrence rates after EMR for large nonpedunculated polyps (>15 mm) with or without adjuvant techniques (snare tip soft coagulation [STSC]/argon plasma coagulation [APC]). An indirect comparison was performed by using the frequentist method. The p-score was calculated to identify preferred intervention. Publication bias was assessed by using a comparison-adjusted funnel plot.

Results

A total of 9 full articles were identified. On direct comparisons, EMR + STSC had 82% reduced odds (odds ratio, .18; 95% confidence interval, .13-.26; P < .001), whereas U-EMR alone had 77% reduced odds (odds ratio, .23; 95% confidence interval, .08-.67; P = .007) of polyp recurrence compared with EMR alone. On indirect comparison, all interventions had significantly lower odds of polyp recurrence compared with EMR alone. The p-score ranking showed that EMR + STSC seems a potential first method in reducing the odds of polyp recurrence, followed by U-EMR, EMR + APC, and EMR alone.

Conclusions

EMR + STSC seems to provide favorable odds for reducing polyp recurrence postresection for large nonpedunculated polyps. Standardization of methods to detect residual polyp and prevent polyp recurrence at the time of EMR are required.

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : APC, CI, OR, RT, STSC, U-EMR


Mappa


© 2024  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 3

P. 326 - marzo 2024 Ritorno al numero
Articolo precedente Articolo precedente
  • The optimal stent for unresectable distal malignant biliary obstruction: Is the exit from the maze of stent selection still not in sight?
  • Atsushi Irisawa
| Articolo seguente Articolo seguente
  • Complete circumferential endoscopic submucosal dissection for early Barrett’s neoplasia
  • Douglas Motomura, Robert Bechara

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.