Abbonarsi

Infraspinatus function impairment after arthroscopic Bankart repair with Hill Sachs remplissage. Isokinetic, functional, and radiographic analysis - 26/04/24

Doi : 10.1016/j.otsr.2024.103812 
Emile Dobelle a, b, , Julie Falguières a, b , Matthieu Ollivier a , Jean-Noël Argenson a , Damien Lami a
a Département d’orthopédie et de traumatologie ISM, CNRS, institut du mouvement et de l’appareil locomoteur, hôpital Sainte-Marguerite, Aix-Marseille université, 270, boulevard Sainte-Marguerite, BP 29, 13274 Marseille, France 
b Institut du mouvement et de l’appareil locomoteur, CHU Marseille Nord, chemin des Bourrely, 13015 Marseille, France 

Corresponding author. Département d’orthopédie et de traumatologie ISM, CNRS, institut du mouvement et de l’appareil locomoteur, hôpital Sainte-Marguerite, Aix-Marseille université, 270, boulevard Sainte-Marguerite, BP 29, 13274 Marseille, France.Département d’orthopédie et de traumatologie ISM, CNRS, institut du mouvement et de l’appareil locomoteur, hôpital Sainte-Marguerite, Aix-Marseille université270, boulevard Sainte-Marguerite, BP 29Marseille13274France

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Purpose

Arthroscopic Bankart repair with Hill Sachs remplissage (BHSR) is an option for anterior shoulder instability with humeral defect. Our hypothesis was that infraspinatus capsulo-tenodesis is an effective solution, with good clinical results and no consequences on shoulder strength and ranges of motion.

Methods

We performed a retrospective case-control study involving 22 patients operated with arthroscopic BHSR. We compared isokinetic evaluation of both shoulders using a dynanometer in concentric, eccentric force and endurance. Ranges of motion were measured using a goniometer and compared to the contralateral unaffected side. Functional assessment included Constant, Rowe, Walch and Duplay and WOSI scores. Healing and fatty degeneration were analyzed with magnetic resonance imaging.

Results

At mean 37.2 months follow-up, 21 patients (95.4%) were satisfied or very satisfied with the intervention. Range of motion in external rotation of the affected side decreased by 10.8° in adduction and 6° at 90° of abduction (p<0.05). Deficit in external rotation strength of the affected side greater than 15% was found in all isokinetic tests (p<0.05). Walch and Duplay, Rowe, WOSI and adjusted Constant average scores were respectively 71.05±14.1 (40–90), 67.63±19.7 (15–100), 34.6%±19.9 (8.43–76.23) and 69.8±13.57 (36.7–101). Postoperative MRI showed good capsulo-tenodesis healing without infraspinatus muscle fatty degeneration.

Conclusion

Arthroscopic BHSR provides satisfactory functional outcomes but significant infraspinatus functional impairments in both strength and ranges of motion in external rotation.

Level of evidence

III; case-control study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Hill Sachs lesion, Remplissage, Instability, Capsulo-tenodesis, Infraspinatus, Isokinetic, Strength, MRI


Mappa


© 2024  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 110 - N° 3

Articolo 103812- maggio 2024 Ritorno al numero
Articolo precedente Articolo precedente
  • Impact of social distancing on traumatic injury incidence during the COVID-19 pandemic: A study using nationwide data from South Korea from 2018 to 2020
  • Kunhyung Bae, Soo-Sung Park, Michael Seungcheol Kang
| Articolo seguente Articolo seguente
  • Faster strength recovery and better strength ratio with arthroscopic Latarjet compared to the open technique: An observational study
  • Antoni Orgiu, Baptiste Boukebous, Haroun Bouhali, Pierre Riou, Marc-Antoine Rousseau, Patrick Boyer

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.