Abbonarsi

Three-dimensional printing technique aids screw insertion into the sustentaculum tali of the internal fixation of intra-articular calcaneal fractures - 25/10/24

Doi : 10.1016/j.otsr.2024.103835 
Bing Wang a, 1, Ce Shi a, 1, Aixiang Zhu a, Fenglei Qiao b, Jingjing Zhou b, Chun Yang a, Yachao Sheng a, Honglan Tang a, Guangsheng Tang c, d, Deguang Wang c, d,
a Department of Traumatic Orthopedics, The Affiliated Suqian Hospital of Xuzhou Medical University, No 138. Huanghe Road, Suqian City, Jiangsu Province, China 
b Department of Medical Imaging, The Affiliated Suqian Hospital of Xuzhou Medical University, No 138. Huanghe Road, Suqian City, Jiangsu Province, China 
c School of Basic Medicine, Xuzhou Medical University, No 209. Tongshan Road, Xuzhou City, Jiangsu Province, China 
d School of Medical Imaging, Xuzhou Medical University, No 209. Tongshan Road, Xuzhou City, Jiangsu Province, China 

Corresponding author. Department of Human Anatomy, Xuzhou Medical University, No 209. Tongshan Road, Xuzhou City, Jiangsu Province, China.Department of Human Anatomy, Xuzhou Medical UniversityNo 209. Tongshan RoadXuzhou CityJiangsu ProvinceChina

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

Treating complex calcaneus fractures remains challenging. This study evaluated the influence of 3D printing and simulation on precision screw insertion into the calcaneus sustentaculum tali (ST).

Hypothesis

3D printing and simulation improve the treatment for calcaneal fracture.

Patients and methods

This retrospective cohort study included 85 patients admitted with 93 Sanders type II–IV intra-articular fractures from January 2015 to June 2020. Multi-slice computed tomography (MSCT) images were used in the conventional group, and MSCT data were used to construct a 3D model of the calcaneus to simulate screw insertion and verify parameter accuracy in the 3D group.

Results

The designed parameters (upward and backward oblique angles and screw-path length) were similar to the actual values in the 3D group (p=0.428,0.287,0.585) but not in the conventional group (p=0.01,0.002,0.023). The Maryland foot functional score, accuracy rate, and average screw number were higher and operative time was shorter in the 3D group (p=0.005,0.007,0.000,0.000).

Discussion

Preoperative simulation using the 3D printing model helped guide the screws into the ST more accurately, lending better-quality treatment for Sanders type II–IV calcaneal fractures.

Level of proof

III; Retrospective case-control study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Calcaneal fractures, Sustentaculum tali, Fracture fixation, Internal fixation


Mappa


© 2024  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 110 - N° 7

Articolo 103835- novembre 2024 Ritorno al numero
Articolo precedente Articolo precedente
  • Dedicated locking plate reduces non-union risk in open ankle fusion in obese patients
  • Claire Nicot, Guillaume David, Clément Marc, Laurent Hubert, Louis Rony
| Articolo seguente Articolo seguente
  • Comments on: “Conservative treatment of fragility fracture of the pelvis: A retrospective study” of T. Kanazawa, T. Ohmori, K. Toda, T. Takigawa, T. Morita, T. Taoaka, T. Ishihara, Y. Ito published in Orthop Traumatol Surg Res 2024;110:103811. doi: 10.1016/j.otsr.2024.103811
  • Waseem Jerjes

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.