Training size predictably improves machine learning-based epileptic seizure forecasting from wearables - 13/12/24

Doi : 10.1016/j.neuri.2024.100184 
Mustafa Halimeh a, Michele Jackson b, Tobias Loddenkemper b, Christian Meisel a, c, d, e,
a Computational Neurology Lab, Department of Neurology and Berlin Institute of Health, Charité - Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany 
b Division of Epilepsy and Clinical Neurophysiology, Boston Children's Hospital, Harvard Medical School, 300 Longwood Ave, Boston, MA 02115, United States of America 
c Center for Stroke Research Berlin, Berlin, Germany 
d NeuroCure Cluster of Excellence, Charité - Universitätsmedizin Berlin, Berlin, Germany 
e Bernstein Center for Computational Neuroscience, Berlin, Germany 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Objective: Wrist-worn wearable devices that monitor autonomous nervous system function and movement have shown promise in providing non-invasive, broadly applicable seizure forecasts that increase in accuracy with larger training size. Nevertheless, challenges related to missing validation, small number of enrolled patients, insufficient training data, and lack of patient seizure cycles data hinder its clinical implementation. Here we sought to prospectively validate a previously implemented seizure forecasting algorithm using a larger cohort of pediatric patients with epilepsy (pwe), improve it by including information on seizure cycles, and (3) assess the utility of precise power-laws to predict performance as a function of dataset size.

Methods: We used video-EEG recordings from 166 pwe as ground-truth for seizures, recorded electrodermal activity (EDA), peripheral body temperature (TEMP), blood volume pulse (BVP), accelerometery (ACC) and applied a deep neural LSTM network model (NN) on these data along with information on 24-hour cycles to forecast seizures in a leave-one-subject-out cross validation. Evaluations were made using improvement over chance (IoC) and the Brier skill score (BSS), which measured the improvement of the NN Brier score compared to the Brier score of a rate-matched random (RMR) forecast.

Results: Performance quantified by IoC and BSS increased with training data following precise power-law scaling laws, thereby exceeding prior reported performance levels from smaller datasets. Including information on 24-hour seizure cycles further improved performance. For the largest training set we achieved significant IoC in 68% of pwe, an IoC of 27.3% and a BSS of 0.087.

Interpretation: Our results validate a previous forecast approach and indicate that performance improves predictably as a function of dataset size following power-law scaling.

Il testo completo di questo articolo è disponibile in PDF.

Highlights

We validate a previously published forecasting algorithm on larger data.
Seizure forecasting performance using wearables predictably improves with data size.
The performance increase follows a precise power-law.
Inclusion of 24-hour time cycle features improved the forecasting performance.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2024  The Author(s). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 5 - N° 1

Articolo 100184- marzo 2025 Ritorno al numero
Articolo precedente Articolo precedente
  • Understanding risk factors of post-stroke mortality
  • David Castro, Nuno Antonio, Ana Marreiros, Hipólito Nzwalo
| Articolo seguente Articolo seguente
  • EEG signal based brain stimulation model to detect epileptic neurological disorders
  • Haewon Byeon, Udit Mahajan, Ashish Kumar, V. Rama Krishna, Mukesh Soni, Monika Bansal

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.