Abbonarsi

Drones reduce the time to defibrillation in a highly visited non-urban area: A randomized simulation-based trial - 13/12/24

Doi : 10.1016/j.ajem.2024.09.036 
Michiel J. van Veelen a, b, , Giovanni Vinetti a, Tomas Dal Cappello a, Frederik Eisendle a, c, Abraham Mejia-Aguilar d, Riccardo Parin e, Rosmarie Oberhammer f, g, Marika Falla a, h, Giacomo Strapazzon a, i
a Institute of Mountain Emergency Medicine, Eurac Research, Bolzano, Italy 
b Department of Sport Science, Medical Section, University of Innsbruck, Innsbruck, Austria 
c Department of Anaesthesiology and Intensive Care Medicine, Medical University of Innsbruck, Innsbruck, Austria 
d Center for Sensing Solutions, Eurac Research, Bolzano, Italy 
e terraXcube, Eurac Research, Bolzano, Italy 
f HELI Helicopter Emergency Medical Services South Tyrol, Bolzano, Italy 
g Department of Anaesthesia and Intensive Care, Emergency Medicine and Pain Therapy, Hospital of Brunico (SABES-ASDAA), Teaching Hospital of Paracelsus Medical University, Brunico, Italy 
h Department of Neurology/Stroke Unit, Hospital of Bolzano (SABES-ASDAA), Teaching Hospital of Paracelsus Medical University, Bolzano, Italy 
i Corpo Nazionale Soccorso Alpino e Speleologico, National Medical School (CNSAS SNaMed), Milano, Italy 

Corresponding author at: Via Ipazia 2, 39100 Bolzano, Italy.Via Ipazia 2Bolzano39100Italy

Abstract

Introduction

Out-of-hospital cardiac arrest (OHCA) has a high global incidence and mortality rate, with early defibrillation significantly improving survival. Our aim was to assess the feasibility of autonomous drone delivery of automated external defibrillators (AED) in a non-urban area with physical barriers and compare the time to defibrillate (TTD) with bystander retrieval from a public access defibrillator (PAD) point and helicopter emergency medical services (HEMS) physician performed defibrillation.

Methods

This randomized simulation-based trial with a cross-over design included bystanders performing AED retrievals either delivered by automated drone flight or on foot from a PAD point, and simulated HEMS interventions. The primary outcome was the time to defibrillation, with secondary outcomes comparing workload, perceived physical effort, and ease of use.

Results

Thirty-six simulations were performed. Drone-delivered AED intervention had a significantly shorter TTD [2.2 (95 % CI 2.0–2.3) min] compared to PAD retrieval [12.4 (95 % CI 10.4–14.4) min] and HEMS [18.2 (95 % CI 17.1–19.2) min].

The self-reported physical effort on a visual analogue scale for drone-delivered AED was significantly lower versus PAD [2.5 (1 – 22) mm vs. 81 (65–99) mm, p = 0.02]. The overall mean workload measured by NASA-TLX was also significantly lower for drone delivery compared to PAD [4.3 (1.2–11.7) vs. 11.9 (5.5–14.5), p = 0.018].

Conclusion

The use of drones for automated AED delivery in a non-urban area with physical barriers is feasible and leads to a shorter time to defibrillation. Drone-delivered AEDs also involve a lower workload and perceived physical effort than AED retrieval on foot.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Drone, AED, Unmanned aerial vehicle, HEMS, PAD, OHCA


Mappa


© 2024  The Authors. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 86

P. 5-10 - dicembre 2024 Ritorno al numero
Articolo precedente Articolo precedente
  • Subject Index
| Articolo seguente Articolo seguente
  • Correlates of improved outcomes in patients with COVID-19 treated in US emergency departments
  • Wendy S. Slutske, Julie M. Kirsch, Thomas M. Piasecki, Karen L. Conner, Brian Williams, Michael C. Fiore, Steven L. Bernstein

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.