Abbonarsi

Coronary artery disease detection using deep learning and ultrahigh-resolution photon-counting coronary CT angiography - 18/02/25

Doi : 10.1016/j.diii.2024.09.012 
Jan M. Brendel a, Jonathan Walterspiel a, Florian Hagen a, Jens Kübler a, Andreas S. Brendlin a, Saif Afat a, Jean-François Paul b, c, Thomas Küstner d, Konstantin Nikolaou a, Meinrad Gawaz e, Simon Greulich e, Patrick Krumm a, , Moritz T. Winkelmann a
a Department of Radiology, Diagnostic and Interventional Radiology, University of Tübingen, 72076, Germany 
b Institut Mutualiste Montsouris, Department of Radiology, Cardiac Imaging, 75014 Paris, France 
c Spimed-AI, 75014 Paris, France 
d Department of Radiology, Diagnostic and Interventional Radiology, Medical Image and Data Analysis (MIDAS.lab), University of Tübingen, 72076, Germany 
e Department of Internal Medicine III, Cardiology and Angiology, University of Tübingen, 72076, Germany 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Highlights

Artificial intelligence shows remarkable performance in detecting significant coronary artery disease on ultrahigh-resolution photon-counting CT.
Artificial intelligence may serve as a valuable pre-reading tool to assist human readers for coronary artery disease detection on photon-counting coronary CT angiography in daily clinical practice.
Integrating artificial intelligence for coronary artery disease detection could improve workflow efficiency and help radiologists manage increasing workloads.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

Purpose

The purpose of this study was to evaluate the diagnostic performance of automated deep learning in the detection of coronary artery disease (CAD) on photon-counting coronary CT angiography (PC-CCTA).

Materials and methods

Consecutive patients with suspected CAD who underwent PC-CCTA between January 2022 and December 2023 were included in this retrospective, single-center study. Non-ultra-high resolution (UHR) PC-CCTA images were analyzed by artificial intelligence using two deep learning models (CorEx, Spimed-AI), and compared to human expert reader assessment using UHR PC-CCTA images. Diagnostic performance for global CAD assessment (at least one significant stenosis ≥ 50 %) was estimated at patient and vessel levels.

Results

A total of 140 patients (96 men, 44 women) with a median age of 60 years (first quartile, 51; third quartile, 68) were evaluated. Significant CAD on UHR PC-CCTA was present in 36/140 patients (25.7 %). The sensitivity, specificity, accuracy, positive predictive value), and negative predictive value of deep learning-based CAD were 97.2 %, 81.7 %, 85.7 %, 64.8 %, and 98.9 %, respectively, at the patient level and 96.6 %, 86.7 %, 88.1 %, 53.8 %, and 99.4 %, respectively, at the vessel level. The area under the receiver operating characteristic curve was 0.90 (95 % CI: 0.83–0.94) at the patient level and 0.92 (95 % CI: 0.89–0.94) at the vessel level.

Conclusion

Automated deep learning shows remarkable performance for the diagnosis of significant CAD on non-UHR PC-CCTA images. AI pre-reading may be of supportive value to the human reader in daily clinical practice to target and validate coronary artery stenosis using UHR PC-CCTA.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Computed tomography, Coronary artery disease, Deep learning, Photon-counting CT, Ultrahigh resolution

Abbreviations : AI, AUC, CAD, CAD-RADS, CCTA, CDTI vol , CI, DLP, FFR, FFRai, PC, PC-CCTA, PPV, NPV, SD, UHR


Mappa


© 2024  The Author(s). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 106 - N° 2

P. 68-75 - febbraio 2025 Ritorno al numero
Articolo precedente Articolo precedente
  • Ultra-high resolution spectral photon-counting CT outperforms dual layer CT for lung imaging: Results of a phantom study
  • Hugo Lacombe, Joey Labour, Fabien de Oliveira, Antoine Robert, Angèle Houmeau, Marjorie Villien, Sara Boccalini, Jean-Paul Beregi, Philippe C. Douek, Joël Greffier, Salim A. Si-Mohamed
| Articolo seguente Articolo seguente
  • Generative AI smartphones: From entertainment to potentially serious risks in radiology
  • Loïc Duron, Philippe Soyer, Augustin Lecler

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.