Abbonarsi

Glucose Testing Methods: A Systematic Review and Meta-Analysis of Diagnostic Accuracy of Point-of-Care Devices for Neonatal Hypoglycemia - 24/02/25

Doi : 10.1016/j.jpeds.2024.114438 
Sophie L. St Clair 1, Caitlyn M. Ulyatt 1, Maria T. Corkin, PhD 1, 2, Libby G. Lord 1, Caroline A. Crowther, MD 1, Jane E. Harding, DPhil 1, Luling Lin, PhD 1,
1 Liggins Institute, The University of Auckland, Auckland, New Zealand 
2 Faculty of Science, School of Psychology, The University of Auckland, Auckland, New Zealand 

Reprint requests: Luling Lin, PhD, Liggins Institute, 85 Park Road, Grafton, Auckland 1023, New Zealand.Liggins Institute85 Park RoadGraftonAuckland1023New Zealand

Abstract

Objective

To evaluate the accuracy of various point-of-care device methodologies for measuring blood glucose concentrations in babies at risk of neonatal hypoglycemia.

Study design

This systematic review and meta-analysis included studies from Ovid MEDLINE, Ovid Embase, and Web of Science up to May 20, 2024. Studies comparing point-of-care testing methods for neonatal blood glucose to a standard laboratory method were included, excluding those on continuous glucose monitoring or conducted before 1990. Two researchers independently assessed inclusion and evaluated risk of bias using QUADAS-2. Sensitivity and specificity were calculated using contingency tables, and diagnostic accuracy was analyzed using hierarchical random-effects modelling. Studies with insufficient data were summarized by estimation direction.

Results

Seventy-one studies were included. The quantitative analysis (n = 31) evaluated glucose oxidase (GO) + photometry (n = 8), glucose-1-dehydrogenase (GDH) + photometry (n = 6), GO + electrochemistry (n = 13), GDH + electrochemistry (n = 12), and hexokinase (HK) + electrochemistry (n = 2). All methods showed high specificity (≥93%), with GO + electrochemistry, GDH + electrochemistry, and HK + electrochemistry showing superior sensitivity. The summary receiver operating characteristic curve confirmed HK + electrochemistry as the most accurate.

Conclusion

Certain point-of-care device methodologies demonstrate greater accuracy in measuring neonatal blood glucose concentrations. Of the methods evaluated, HK + electrochemistry proved to be the most reliable. However, the limited number of studies using this method suggests the need for further research to confirm these findings across diverse settings and populations.

Systematic review registration

PROSPERO on December 29, 2023 (CRD42023488539).

Il testo completo di questo articolo è disponibile in PDF.

Keywords : newborn, glycemia, diagnostic techniques and procedures

Abbreviations : HK, GO, GDH, SROC


Mappa


© 2024  The Author(s). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 278

Articolo 114438- marzo 2025 Ritorno al numero
Articolo precedente Articolo precedente
  • Rash Decisions: Improving Pediatrician Skills in Dermatologic Diagnosis
  • Joel Gupta, Cathryn Sibbald, Miriam Weinstein, Martin Pusic, Madeline Bell, Nikolas MacLellan, Robert Bobotsis, Rashie Brar, Kathy Boutis
| Articolo seguente Articolo seguente
  • Parental Perceptions of Early Childhood In-Home Research with Monitoring: A Qualitative Study
  • Gabriella B. Smith, Mickayla D. Jones, Mary J. Akel, Leonardo Barrera, Marie Heffernan, Patrick Seed, Michelle L. Macy, Stephanie A. Fisher, Leena B. Mithal

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.