Abbonarsi

Prospective, multicenter, self-controlled clinical trial on the effectiveness and safety of a cable-transmission magnetically controlled capsule endoscopy system for the examination of upper GI diseases (with video) - 04/04/25

Doi : 10.1016/j.gie.2024.07.028 
Yuan Tian, MD 1, Shiyu Du, MD 2, Hong Liu, MD 3, Hang Yu, MD 1, Ruxue Bai, MD 2, Hui Su, MD 3, Xinyue Guo, BS 1, Yan He, BS 1, Zhenmei Song, MD 2, Yanming Chen, BS 2, Qian Li, MD 3, Jing Wang, MD 3, Wenming Huang, BS 4, Long Rong, MD 1,
1 Department of Endoscopy Center, Peking University First Hospital, Beijing, China 
2 Gastroenterology Department, China-Japan Friendship Hospital, Beijing, China 
3 Gastroenterology Department, Capital Medical University affiliated Beijing Shijitan Hospital, Beijing, China 
4 Hygea Medical Technology Co, Beijing, China 

Reprint requests: Long Rong, MD, Department of Endoscopy Center, Peking University First Hospital, No. 8 Xishiku St, Beijing 100034, China.Department of Endoscopy CenterPeking University First HospitalNo. 8 Xishiku StBeijing100034China

Abstract

Background and Aims

Many GI disorders and precancerous conditions often present asymptomatically, leading to delayed patient diagnoses and treatment interventions. In this study, we developed a novel cable-transmission magnetically controlled capsule endoscopy (CT-MCCE) system for detecting GI diseases and assessed its safety and feasibility through clinical trials.

Methods

This prospective, multicenter trial compared CT-MCCE with conventional gastroscopy in patients aged 18 to 75 years with upper GI tract diseases between October 2022 and July 2023. The primary endpoints were the evaluation of sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) in the detection of focal lesions within the esophagus, stomach, and duodenal bulb using CT-MCCE.

Results

One hundred eighty individuals (mean age, 43.1 years; 52.22% women) were recruited from 3 hospitals in China. CT-MCCE detected lesions in the esophagus with a sensitivity of 97.22%, specificity of 100%, PPV of 100%, NPV of 98.18%, and accuracy of 98.89%; detected gastric focal lesions in the entire stomach with a sensitivity of 96.81%, specificity of 98.84%, PPV of 98.91%, NPV of 96.59%, and accuracy of 97.78%; and detected lesions in the duodenal bulb with a sensitivity of 100%, specificity of 100%, PPV of 100%, NPV of 100%, and accuracy of 100%. There were no significant differences between CT-MCCE and EGD regarding the cleanliness of the upper GI tract and visibility of the upper GI mucosa. However, CT-MCCE was associated with a lower incidence of discomfort than EGD (P < .001).

Conclusions

The diagnostic performance of CT-MCCE is comparable with that of EGD in the completion of upper GI tract examinations and lesion detection. Furthermore, the improved tolerance of CT-MCCE in detecting upper GI diseases was noted without any observed adverse events. (Clinical trial registration number: ChiCTR2200063630.)

Il testo completo di questo articolo è disponibile in PDF.

Graphical abstract




Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : CI, CT-MCCE, MCCE, NPV, PPV


Mappa


© 2025  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 101 - N° 4

P. 804 - aprile 2025 Ritorno al numero
Articolo precedente Articolo precedente
  • Evaluating the efficacy of a novel hemostatic powder compared with traditional treatments in nonvariceal upper GI bleeding: a multicenter, randomized, noninferiority study
  • Da Hyun Jung, Jun Chul Park, Joon Sung Kim, Moon Won Lee, Hyuk Lee, Gwang Ha Kim
| Articolo seguente Articolo seguente
  • Automatic endoscopic gastroplasty for the treatment of obesity: results from a prospective multicenter study (with video)
  • Ivo Boskoski, Gontrand Lopez-Nava, Asokkumar Ravishankar, Vincenzo Bove, Maria Valeria Matteo, Martina De Siena, Valerio Pontecorvi, Giulia Giannetti, Amerigo Iaconelli, Cristiano Spada, Steven E. Shamah

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.