Jacketed respiratory inductive plethysmography in rats: A translational non-invasive method for cardiorespiratory exercise monitoring - 08/04/25

Doi : 10.1016/j.rmr.2025.02.090 
A. Cambier 1, 2, , S. Tanguy 1, T. Flenet 2, F. Boucher 1
1 Physiologie cardio-respiratoire expérimentale théorique et appliquée, TIMC, University Grenoble Alpes, France 
2 R&D département, ETISENSE, Lyon, France 

Corresponding author.

Riassunto

Introduction

Respiratory inductive plethysmography (RIP) is one of the least restrictive methods for evaluating pulmonary ventilation. It has been used in humans since the 1980s as one of the clinical tests for functional exploration of the respiratory system under different conditions (sleep, rest or exercise) in healthy and in respiratory pathology patients. This method has been adapted and integrated into jacketed telemetry systems used in preclinical large animal research (safety pharmacology, fundamental or applied research, etc.). Thanks to the recent miniaturisation of jacketed telemetric systems, a new solution is available for assessing respiratory function combined with ECG in small mammals [1] (i.e. rats). As exercise was initially used to validate the measurement accuracy of dual-band respiratory inductance plethysmography in humans, it was of interest to qualify this solution in a similar way in rats. The aim is to assess the feasibility of a translational model using this technology to monitor physiological changes associated with exercise on a treadmill.

Methods

For this purpose, male Wistar rats (n=10.8-9 weeks old) were exposed to an incremental treadmill exercise protocol with speed levels from 5 to 45cm. s-1. Respiratory parameters (respiratory rate (RespR), minute ventilation (VM), Tidal volume (VT)) and peak inspiratory and expiratory flow (PIF, PEF, PENH) as well as cardiac (heart rate (HR)) and activity level (AL) were continuously monitored and analyzed over the last 30seconds of each level.

Results

All animals were successfully fitted with the device and returned to their home cages. The control values measured after stabilization were for RespR 165±8brpm, HR 407±9bpm and AL 24±4mg. At least all animals ran successfully on the treadmill with the vest up to 35cm/sec (n=10), some reaching 45cm/sec (n=6). For the maximum plateau, exercise induced a significant physiological increase (Figure 1) in respiratory parameters (RespR +74%, 116±26 brpm, P<0.01**//MV +334%, 1099±197mL. min-1, P<0.01**//VT +197%, 4±1mL, P<0.01**), as well as HR (+36%, 140±13 bpm, P<0.05*) and AL (+2358%, 504±57 bpm, P<0.05*). PIF and PEF showed a significant increase of 86±9ml. s-1 and 52±11mL. s- respectively. enhanced Pause (PENH) remained stable during exercise indicating no significant variation of airflow limitation.

Conclusion

In conclusion, this new telemetry jacket can be used to monitor the adaptation of respiratory parameters during a standard forced exercise protocol and in a non-invasive way in rats. It is convenient to use and well tolerated by the animal. This alternative method could be used to refine respiratory monitoring in exercise protocols and offers new perspectives for studying pathological and/or pharmacological phenotype alterations in various models.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2025  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 42 - N° 4

P. 227 - aprile 2025 Ritorno al numero
Articolo precedente Articolo precedente
  • Chronic and intermittent hypoxias lead to disrupted clock genes expression in mouse lung tissues: Implications for lung cell senescence
  • V. Gros, E. arcos, J. Jacquet, E. Born, J.A. De Freitas, S. Abid, D. Beaulieu, N. Vienney, A. Houssaini, L. Lipskaia, C. Jourdan Le Saux, O. Bischof, H. Duez, B. Pourcet, L. Boyer, S. Adnot
| Articolo seguente Articolo seguente
  • Une méthode simple pour dépister la distension dynamique pulmonaire : le test de tachypnée rythmée par un métronome
  • G. Simon, J. Moulinié, Q. Lorber, M. Hayot, F. Gouzi

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.