Abbonarsi

Reference values for liver stiffness in children using shear-wave elastography - 11/07/25

Doi : 10.1016/j.arcped.2025.03.006 
Célia Charlier a, Saskia Vande Perre a, Béatrice Dubern b, Claire Apte-Dubuisson b, Etienne Audureau c, Margaux Bertrand a, Hubert Ducou le Pointe a, Eléonore Blondiaux a, d, ⁎
a Department of Radiology, Trousseau Hospital, APHP, Sorbonne Université, Paris, France 
b Department of Pediatric Nutrition and Gastroenterology, Trousseau Hospital, APHP, Sorbonne Université, Paris, France 
c Unité de Recherche Clinique, Henri Mondor Hospital, AP-HP and Université Paris-Est, A-TVB DHU, CEpiA (Clinical Epidemiology and Aging), Unit EA4393, UPEC, F-94000, Créteil, France 
d Laboratoire d'Imagerie Biomédicale, Sorbonne Université, INSERM, CNRS, Paris, France 

⁎Corresponding author at: Faculté de Médecine, APHP, Sorbonne Université, Laboratoire d’Imagerie Biomédicale, INSERM 1146, CNRS 7371, Department of Imaging, Hôpital Armand-Trousseau, 26 Avenue du Dr Arnold Netter, 75012, Paris, France.Faculté de MédecineAPHPSorbonne UniversitéLaboratoire d’Imagerie BiomédicaleINSERM 1146CNRS 7371Department of ImagingHôpital Armand-Trousseau26 Avenue du Dr Arnold NetterParis75012France

Abstract

Background

Ultrasound shear wave elastography (SWE) measures liver stiffness non-invasively in chronic liver diseases. Reference values in healthy children by age are needed in clinical practice.

Objectives

Our study aimed to measure the reference values for liver elasticity by 2D SWE in a pediatric population stratified by age.

Materials and methods

This retrospective study included 266 children without liver disease referred for an abdominal or renal ultrasonography from February 2022 to April 2022. Shear wave elasticity and shear wave speed were measured with a convex (6C1) or linear (SL15–4) transducer with a Canon Aplio 500 Aplio system performed for another reason in healthy children aged 0 to 19 years distributed in five age groups.

Results

Median liver elasticity value was 5.50 kPa (interquartile range [IQR] 4.9–6.3) overall. Global analyses revealed values decreasing with increasing age from newborn to adolescence (elasticity: 6.0 kPa [IQR 5.4–6.5] to 5.3 kPa [IQR 4.7–6.4]; speed: 1.41 m/s [IQR 1.34–1.47] to 1.33 m/s [IQR 1.27–1.46], p < 10–3). Elasticity values were lower with the convex than linear transducer (5.20 kPa [IQR 4.7–5.8] vs 6.2 kPa [IQR 5.6–6.6], p < 10–4). Elasticity values increase with increasing age if we study each probe individually (from 1 year old to older). Median elasticity values were not associated with sex after adjustment for age or with BMI.

Conclusion

Our study provides reference values for liver elasticity in healthy children by age and for two probes using an Aplio system. Liver elasticity values differed according to the probe used.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Liver stiffness, Children, Shear wave elastography, Ultrasound, Age, Transducer


Mappa


© 2025  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 32 - N° 5

P. 322-328 - luglio 2025 Ritorno al numero
Articolo precedente Articolo precedente
  • Prevalence of risk factors for developing childhood obesity in maternity
  • Hélène Thibault, Marie Pailler, Caroline Carriere, Pascal Barat, Mélanie Le Goff, Nadira Ghemini, Loic Sentilhes, Muriel Rebola, Vincent Rigalleau, Thierry Lamireau
| Articolo seguente Articolo seguente
  • French childminder knowledge of pediatric guidelines for screen use: An observational study
  • C. Allet, M. Samaille, A.D. Marq, M. Bailhache

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.