Abbonarsi

Forced oscillatory technique R5-19 values correlate with spirometry FEV1/FVC in severe eosinophilic asthma. An observational, prospective, cohort study - 01/09/25

Doi : 10.1016/j.rmed.2025.108260 
Claudio Tirelli a, , Elena Maria Parazzini a, Lucia Sacchi b, Giulia Carone a, Francesca Pescol b, Sara Maggioni a, Luca Alessandro Belmonte a, Cristina Albrici a, Simone Contino a, Beatrice Re a, Benedetta Mosole a, Michele Mondoni a, , Stefano Centanni a
a Respiratory Unit, ASST Santi Paolo e Carlo, Department of Health Sciences, Università degli Studi di Milano, 20142 Milan, Italy 
b Department of Electrical, Computer and Biomedical Engineering, Università degli Studi di Pavia, Italy 

Corresponding author. ⁎⁎ Corresponding author.

Abstract

Introduction

Severe asthma affects 3–10 % of asthmatic patients. Biologic therapies can act as disease modifying agents in severe asthma. The prevalence of small airways dysfunction (SAD) increases with asthma severity. Forced Oscillatory Technique (FOT) is a reliable method for studying small airways. The aim of the study was to analyze FOT parameters in a cohort of eosinophilic severe asthma patients naïve of biologic therapy, and to describe the presence of correlation with spirometry data. Variations of FOT parameters after 6 and 12 months from the start of biologic therapy were also prospectively recorded and analyzed.

Methods

47 severe eosinophilic asthma patients were consecutively enrolled. FOT, spirometry data, levels of asthma biomarkers, number of exacerbations, Asthma Control Test (ACT) were determined at baseline (T0: patients naïve of biologic treatment) and after 6 and 12 months.

Results

at T0, a significant linear correlation was found between R5-19 and FEV1/FVC (Forced expiratory volume in 1 s/Forced Vital Capacity) values (p = 0.0008). At T0, FOT R5-19 values were more elevated in obstructed patients. The cut-off value of R5-19 that best discriminates the presence of obstruction (FEV1/FVC < 0.70) was determined at 0.81 cmH 2 O/(L/s) (sensitivity 0.58, specificity 0.76, ROC-AUC 0.67). A significant relationship was found between FEV1/FVC and FOT R5-19 also after 6 (p = 0.007) and 12 months (p = 0.027) of biologic therapy. No significant correlations were found between any other FOT parameter and blood eosinophils count, FeNO, number of exacerbations or ACT.

Conclusions

FOT R5-19 values correlate with FEV1/FVC and are significantly higher in obstruction. This correlation could be explained by the higher resistances of small airways in obstructed patients.

Il testo completo di questo articolo è disponibile in PDF.

Highlights

FOT R5-19 correlates with FEV1/FVC in patients naive of biologic therapy.
FOT R5-19 values are significantly more elevated in obstructed patients.
The correlation is due to small airways higher resistances in obstructed patients.
The R5-19 identified cut-off value for best detect obstruction is 0.81 cmH 2 O/(L/s).
FOT R5-19 and FEV1/FVC correlate also after 6 and 12 months of biologic therapy.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : FOT, R5-19, Severe asthma, Eosinophils, Small airways disease, Oscillometry


Mappa


© 2025  The Authors. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 247

Articolo 108260- ottobre 2025 Ritorno al numero
Articolo precedente Articolo precedente
  • Public health insights of patients with asthma receiving primary, specialist or mixed care in Singapore using data from the SDG-CARE Asthma Registry
  • Mariko Siyue Koh, Xiaomeng Xu, Sean Shao Wei Lam, Jun Tian Wu, Priyan Ratnasingham, Ricco Marsel, Marcus Eng Hock Ong, Ngiap Chuan Tan, Chian Min Loo, David Bruce Matchar
| Articolo seguente Articolo seguente
  • Association between initial treatment response and prognosis in acute exacerbations of idiopathic pulmonary fibrosis treated with steroid pulse therapy
  • Tsuyoshi Sasada, Chigusa Shirakawa, Kazuma Nagata, Katsuyuki Furuta, Ryosuke Hirabayashi, Yuki Sato, Atsushi Nakagawa, Keisuke Tomii, Ryo Tachikawa

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.