Abbonarsi

Pulse Arrival Velocity for Tracking Exercise-Induced Blood Pressure Changes in Children and Adolescents - 06/01/26

Doi : 10.1016/j.hlc.2025.09.005 
Luke E. Ryan, BEng a, Melanie M. Clarke, PhD a, , Daniel Ray, PhD a, Jonathan P. Glenning, BBiomed a, b, Hilary A. Harrington, MN a, Joseph J. Smolich, PhD a, b, Michael M.H. Cheung, MD a, b, c, Jonathan P. Mynard, PhD a, b, d,
a Heart Research, Murdoch Children’s Research Institute, Parkville, VIC, Australia 
b Department of Paediatrics, The University of Melbourne, Parkville, VIC, Australia 
c Department of Cardiology, Royal Children’s Hospital, Parkville, VIC, Australia 
d Department of Biomedical Engineering, The University of Melbourne, Parkville, VIC, Australia 

Corresponding author at: Heart Research, Murdoch Children’s Research Institute, 50 Flemington Road, Parkville, VIC 3052, Australia Heart Research Murdoch Children’s Research Institute 50 Flemington Road Parkville Vic 3052 Australia

Abstract

Background

The potential of cuffless blood pressure (BP) monitoring in children and adolescents is unclear. Although measurement of pulse arrival time (PAT) underlies many cuffless BP technologies, the pulse propagation distance (L) (from heart to measurement location) varies significantly during childhood growth and is likely to confound the desired relationship between PAT and BP in population-based algorithms. This study investigated whether the newly proposed pulse arrival velocity (PAV) (PAV=L/PAT) holds potential for improved tracking of exercise-induced BP changes in children and adolescents.

Method

In 38 included paediatric participants (aged 12.3±3.9 years) undergoing Bruce protocol exercise testing, regression and leave-one-out cross-validation analyses were used to assess performance of PAT and PAV for estimating exercise-induced BP changes. The results were contextualised to BP validation standards.

Results

With exercise, systolic BP increases of 36.1±15.8 mmHg were estimated by PAT-based and PAV-based models, with errors of 0.0±9.1 and 0.0±7.6 mmHg, respectively; the latter falling within the Association for the Advancement of Medical Instrumentation (AAMI) criteria of 5±8 mmHg, with high correlation (r=0.87). Diastolic BP changes (12.1±9.7 mmHg) were also estimated by PAV within the AAMI criteria (0.0±7.0 mmHg) but with modest correlation (r=0.51). Including heart rate, age, sex, or height did not improve model performance. PAV outperformed baseline models for systolic but not diastolic BP.

Conclusions

PAV shows potential for systolic BP tracking during exercise in children and adolescents. By accounting for variability in propagation length, PAV may provide better results than PAT in cuffless BP technology.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Cuffless blood pressure, Paediatrics, Pulse arrival time


Mappa


© 2025  The Author(s). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 35 - N° 1

P. 74-81 - gennaio 2026 Ritorno al numero
Articolo precedente Articolo precedente
  • Stepwise Approach to Ventricular Tachycardia Ablation in Structural Heart Disease
  • Juan Mundisugih, Ashwin Bhaskaran, Kaimin Huang, Kasun De Silva, Samual Turnbull, Tai Chung So, Kenji Hashimoto, Anunay Gupta, Richard G. Bennett, Yasuhito Kotake, Max Bickley, Timothy Campbell, Saurabh Kumar
| Articolo seguente Articolo seguente
  • Attainment of Low-Density Lipoprotein Cholesterol Goals and Statin Use in Patients With Atherosclerotic Cardiovascular Disease in Australian General Practice: Are We Doing Enough?
  • Ralph G. Audehm, Danny Liew, Gerald F. Watts, Charlotte Hespe, Meherin Rahman, Anna Williamson, Catherine Sciascia, Ravi Santani, Andrew M. Tonkin

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.