Advances in acquisition and post-processing optimization of IVIM MRI for brain imaging: A systematic review - 09/01/26

Doi : 10.1016/j.neuri.2025.100256 
Abhijith S. a, Saikiran Pendem a, , Rajagopal Kadavigere b,  Priyanka a, Dharmesh Singh c, Priya P.S. b
a Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, India 
b Department of Radiodiagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, India 
c Central Research Institute – Global Scientific Collaboration, United Imaging Healthcare, Shanghai, China 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Purpose

Diffusion-weighted MRI is widely used to probe brain microstructure, but its signal reflects both diffusion and perfusion effects. Intravoxel Incoherent Motion (IVIM) MRI enables non-contrast separation of these components, offering potential clinical value in neuroimaging. However, clinical translation remains limited due to variability in acquisition and post-processing methods. This systematic review evaluates optimization strategies aimed at improving the accuracy, reproducibility, and clinical utility of IVIM parameters in brain.

Methods

Registered in PROSPERO and conducted according to PRISMA guidelines, a systematic search across five databases was performed. Original peer-reviewed studies focusing on optimization of IVIM acquisition or post-processing in human brain imaging were included, while reviews and studies lacking methodological detail were excluded. Study quality was assessed using a customized QUADAS-2 tool. Due to methodological heterogeneity, an effect direction plot was applied instead of meta-analysis.

Results

Out of 1,668 identified records, 14 studies were included. Acquisition strategies such as optimised b-value sampling, cardiac gating, and advanced sequences reduced parameter variability by up to 40 %. Post-processing methods, including Bayesian fitting, deep learning–based models, and advanced denoising, improved parameter accuracy by up to 99 % and precision by up to 95 %. Effect direction analysis demonstrated significant positive effects on accuracy and clinical utility (p < 0.001) and repeatability (p < 0.05), while scan-time reduction showed no significant benefit (p > 0.05). No study reported gold-standard validation.

Conclusion

Optimization of IVIM acquisition and post-processing enhances parameter robustness and reproducibility in brain MRI, though protocol heterogeneity remains a major obstacle to standardization and clinical adoption.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Intravoxel incoherent motion, Diffusion MRI, Parameter optimization, b-value sampling, Post-processing


Mappa


© 2026  The Author(s). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 6 - N° 1

Articolo 100256- marzo 2026 Ritorno al numero
Articolo precedente Articolo precedente
  • 15 Years of optimizers in medical deep learning: A systematic review
  • Selorm Adablanu, Utpal Barman, Dulumani Das
| Articolo seguente Articolo seguente
  • EEG-based classification in psychiatry using motif discovery
  • Melanija Kraljevska, Kateřina Hlaváčková-Schindler, Lukas Miklautz, Claudia Plant

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.