CleanEEG: A U-Net based deep learning framework for robust EEG artifact removal - 05/02/26

Doi : 10.1016/j.neuri.2026.100264 
Dhruva P. Achar a, Shavantrevva Bilakeri a, Karunakar A. Kotegar , a, b , Kurupath Radhakrishnan c
a Manipal Institute of Technology, Manipal Academy of Higher Education, Manipal, India 
b Department of Computer Applications, Manipal University Jaipur, Jaipur, Rajasthan, 303007, India 
c Department of Neurosciences, Avitis Institute of Medical Sciences, Nemmara, Palakkad, Kerala, 678508, India 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Highlights

Developed CleanEEG, a deep learning model for automated EEG artifact removal.
Trained and validated on sleep EEG data from 25 patients with drug-resistant epilepsy.
Achieved low RRMSE and high correlation across all electrodes.
Removes artifacts while preserving epileptiform waveforms.
Demonstrated effective generalization to unseen awake EEG data.

Il testo completo di questo articolo è disponibile in PDF.

Abstract

High-frequency oscillations (HFOs) are vital biomarkers for identifying the seizure onset zone (SOZ) in patients with drug-resistant epilepsy (DRE). However, EEG artifacts especially muscle and power-line noise overlapping with the HFO frequency range (80–250 Hz) pose significant challenges for accurate detection. Traditional artifact removal methods like independent component analysis (ICA) are labor-intensive and subjective, highlighting the need for automated pre-processing techniques. This study introduces CleanEEG, a U-Net based encoder–decoder model designed to automate artifact removal from clinical EEG. CleanEEG was trained on paired noisy and clean sleep EEG segments from 25 DRE patients (177 segment pairs) at a 512 Hz sampling rate, with clean targets generated through ICA pre-processing. Model performance was quantitatively evaluated on an independent validation set comprising 24 segment pairs from six separate patients excluded from training. Evaluation metrics included relative root mean square error (RRMSE), correlation coefficient (CC), and signal-to-noise ratio (SNR). CleanEEG effectively removed muscle and power-line noise artifacts while preserving important clinical features such as interictal epileptiform discharges (IEDs) and brief potentially ictal rhythmic discharges (BIRDs). The model significantly improved signal quality across electrodes, reducing reconstruction errors and increasing SNR. Additionally, CleanEEG preserved neural activity without introducing distortions and qualitatively demonstrated artifact removal capability on unseen awake EEG data. In a representative DRE patient, critical spatial patterns of HFOs were maintained, essential for accurate SOZ localization. Overall, CleanEEG offers an automated, robust, and efficient solution for artifact removal, enhancing diagnostic accuracy in epilepsy monitoring and HFO analysis, particularly in long-term scalp EEG recordings.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Scalp EEG, EEG artifact removal, Deep learning, Epilepsy, Signal reconstruction, HFO, IED


Mappa


© 2026  The Authors. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 6 - N° 1

Articolo 100264- marzo 2026 Ritorno al numero
Articolo precedente Articolo precedente
  • A proof-of-concept study on the use of large language models for assessing research methodology in neuroimaging
  • Brock Pluimer, Apeksha Sridhar, Ishtiaq Mawla, Helen Mengxuan Wu, Roshni Lulla, Sarah Hennessy, Patrick Sadil, Rishab Iyer, Eric Ichesco, Anson Kairys, Max Egan, Jonas Kaplan, Richard E. Harris
| Articolo seguente Articolo seguente
  • From epilepsy seizure classification to detection: A deep learning-based approach for raw EEG signals
  • Davy Darankoum, Manon Villalba, Clélia Allioux, Baptiste Caraballo, Carine Dumont, Eloïse Gronlier, Corinne Roucard, Yann Roche, Chloé Habermacher, Sergei Grudinin, Julien Volle

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.