Abbonarsi

Do Patient-Specific Guides accurately correct lower limb deformities in children? Preliminary outcomes - 28/03/26

Doi : 10.1016/j.otsr.2025.104431 
Virginie Nguyen-Khac a, b, ⁎ , Anne-Laure Simon b, Brice Ilharreborde b, Laurent Gajny c, Franck Fitoussi a, d, Alexandra Alves a, Raphael Vialle a, Elie Saghbini a, Manon Bachy a, d, e
a Sorbonne University – Armand Trousseau Hospital, AP-HP, 26 Avenue du Docteur-Arnold-Netter, 75012 Paris, France 
b Paris Cité University – Robert Debré Hospital, AP-HP, 48 Boulevard Sérurier, 75019 Paris, France 
c Georges Charpak Institute of Human Biomechanics, ENSAM, 151 Boulevard de l’Hôpital, 75013 Paris, France 
d STREAM, CRMR Trousseau Site for Limb Anomalies in Children, Anddi-Rares Network, 26 Avenue du Docteur-Arnold-Netter, 75012 Paris, France 
e GRC 26 Image, Sorbonne University – Armand Trousseau Hospital, AP-HP, 26 Avenue du Docteur-Arnold-Netter, 75012 Paris, France 

⁎ Corresponding author.

Abstract

Introduction

Over the past decade, the use of patient-specific instrumentation (PSI) has increased exponentially as a means of improving surgical precision. In pediatric orthopedics, its adoption is more recent and differs from adult applications due to the unique characteristics of pediatric deformities and anatomical constraints, particularly the need to preserve the physis. This study aimed to assess the reliability and accuracy of PSI in performing lower limb long bone osteotomies in children.

Hypothesis

Planned corrections are comparable to the achieved corrections.

Patients and methods

This bicentric retrospective study included all PSI-assisted lower limb osteotomies performed since 2021. PSI guides were developed using bilateral CT scans. Demographic data, clinical outcomes at the final follow-up, and any complications were recorded. In all cases, postoperative three-dimensional (3D) reconstruction was performed using low-dose biplanar stereo radiography (EOS) and compared to the preoperative CT-based surgical plan. For each osteotomy, 3D measurements of the primary correction in all three planes were analyzed. Postoperative reliability was defined as the difference between the preoperative plan and the achieved correction (Δ angle). A threshold of ±3 ° was used to assess the accuracy of PSI.

Results

Eighteen patients (21 osteotomies, mean age 14.6 ± 3.4 years) were included: 52% femoral (n = 11) and 48% tibial (n = 10). At a mean follow-up of 10 ± 5 months, one intraoperative and three postoperative complications were observed. Two patients reported residual pain at the final follow-up.

Planned corrections ranged from 9 ° to 85 °, with 62% exceeding 15 °. The mean Δ angle was 11 °, with no significant difference overall (p = 0.06), but a trend toward undercorrection was observed in cases with planned corrections >15 ° (p = 0.03).

Discussion

The use of PSI in pediatric lower limb osteotomies tends to result in undercorrection compared to the planification, particularly in case of severe deformity. This may be explained by the greater magnitude of corrections typically required in pediatric patients compared to adults. Although these findings require confirmation through larger cohorts and 3D postoperative analysis, they should be considered when using PSI in pediatric lower limb osteotomies.

Level of evidence

III; Retrospective case-control study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Patient-specific instrumentation, Lower limb osteotomy, 3D planification, Pediatrics


Mappa


© 2025  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 112 - N° 2

Articolo 104431- aprile 2026 Ritorno al numero
Articolo precedente Articolo precedente
  • Contribution of a new augmented reality system in total knee arthroplasty implantation. An in vivo, prospective, non-comparative study of 60 cases
  • Grégoire Duval, Aurore Emery, Martin Tripon, Robin Oger, Julen Dunet, Gaëlle Maroteau, Christophe Hulet
| Articolo seguente Articolo seguente
  • Can anterior midfoot tarsectomy procedure be improved using patient-specific cutting guide? An experimental study
  • Julie Mathieu, Guillaume Lamouroux, Mathilde Gatti, François Canovas, Pierre-Emmanuel Chammas, Louis Dagneaux

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.