Assessment of a percutaneous iliosacral screw insertion simulator - 06/11/09

Doi : 10.1016/j.otsr.2009.07.005 
J. Tonetti , L. Vadcard, P. Girard, M. Dubois, P. Merloz, J. Troccaz
Orthopaedic and Traumatology Department, Michallon Hospital, BP 217, 38043, Grenoble cedex 09, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Background

Navigational simulator use for specialized training purposes is rather uncommon in orthopaedic and trauma surgery. However, it reveals providing a valuable tool to train orthopaedic surgeons and help them to plan complex surgical procedures.

Purpose

This work’s objective was to assess educational efficiency of a path simulator under fluoroscopic guidance applied to sacroiliac joint percutaneous screw fixation.

Materials and methods

We evaluated 23 surgeons’ accuracy inserting a guide-wire in a human cadaver experiment, following a pre-established procedure. These medical trainees were defined in three prospective respects: novice or skilled; with or without theoretical knowledge; with or without surgical procedure familiarity. The screw insertion in the human cadaver was performed in two different settings: either without prior training for a first group (G1) or after simulator guidance in the second group (G2). Analysed criteria for each tested surgeon included the number of intraoperative X-rays taken in order to achieve the surgical procedure as well as an iatrogenic index reflecting the surgeon’s ability to detect any hazardous trajectory at the time of performing said procedure.

Results

An average number of 13 X-rays was required for wire implantation by the G1 group. G2 group, assisted by the simulator use, required an average of 10 X-rays. A substantial difference was especially observed within the novice sub-group (N), with an average of 12.75 X-rays for the G1 category and an average of 8.5 X-rays for the G2 category. In the second sub-group of operators devoid of procedural knowledge (P−), a significant difference was found, since 12 X-rays appeared on average required in the G1 group versus six in the G2 group. Finally, within the sub-group of operators with technical knowledge (T+), a significant difference also was found since an average of 16 X-rays was required in the G1 versus an average 10.8 X-rays in the G2 group. As far as the iatrogenic index is concerned, we were unable to observe any significant difference between the groups.

Discussion

Despite some methodological variations, we were able to demonstrate the simulator’s efficiency in familiarizing the operator with the use of a 2D imaging system as a first step facilitating the procedure conduct in the real 3D patient environment. Novice surgeons (N) having a good lumbosacral joint anatomy knowledge although devoid of specific surgical technique knowledge were the ones who most benefited from this guiding tool. Analysis of the training data collected during simulator’s use helps orientating the prospective surgeon toward possession of not yet acquired learning points. This educational program can easily be extended to any other percutaneous technique requiring fluoroscopic control guidance.

Level of evidence

Level III prospective diagnostic study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Trauma surgery, Simulator, Virtual reality surgery, Sacroiliac joint screw insertion, Computer-based medical training


Mappa


© 2009  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 95 - N° 7

P. 471-477 - novembre 2009 Ritorno al numero
Articolo precedente Articolo precedente
  • Musculotendinous infraspinatus ruptures: An overview
  • G. Walch, L. Nové-Josserand, J.-P. Liotard, E. Noël
| Articolo seguente Articolo seguente
  • Cementless cups do not increase osteolysis risk in metal-on-metal total hip arthroplasty
  • J. Beldame, F. Carreras, P. Oger, P. Beaufils

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.