Abbonarsi

Does hyperflex total knee design improve postoperative active flexion? - 07/06/10

Doi : 10.1016/j.otsr.2009.11.015 
P. Massin a, , F.-R. Dupuy a, H. Khlifi c, C. Fornasieri c, T. De Polignac c, P. Schifrine c, C. Farenq d, P. Mertl b
a Department of Orthopaedic Surgery, Bichat Hospital, North-Paris Teaching Hospitals Group, Paris Diderot Medical School, 46, rue Henri-Huchard, 75877 Paris cedex 18, France 
b Department of Orthopaedic Surgery, North Hospital, Amiens Teaching Hospital Center, place Victor-Pauchet, 80054 Amiens cedex 1, France 
c General Private Hospital, 4, chemin Tour-de-la-Reine, 74000 Annecy, France 
d Saint-Jean Private Hospital, 36, avenue Bouisson-Bertrand, 34000 Montpellier, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Introduction

The rotating platform flexion (RPF) Sigma total knee prosthesis (DePuy; Warsaw, Indiana) was designed for maintaining the contact of the condyles with their corresponding tibial plateau throughout the high-flexion range. However, this requires an additional 3-mm bone cut of the posterior condyles. Compared to the conventional design, this modification is intended to improve the flexion range. This hypothesis was tested by studying the increase in flexion (flexion gain, range of motion [ROM], active flexion) of 59 consecutive patients who had received the hyperflex design implant (RPF), whose preoperative mobility values were retrospectively compared to these same values in another 59 consecutive matched patients who had received an implant with the conventional design of the same implant (rotating platform [RP]) between June 2005 and June 2006. Postoperative mobility was measured visually with a goniometer.

Patients and methods

Only osteoarthritic knees were eligible to be included. Knees with more than 20° flexion contracture or less than 90° flexion, and patients with a body mass index (BMI) greater than 30 were excluded. Both groups were comparable with regard to age, preoperative mobility values, and BMI. The sex ratio differed significantly, but preoperative mobility did not differ significantly in male and female patients in the RP and in the RPF groups. The difference in sex ratio did not appear to be a bias influencing preoperative mobility.

Results

Overall, the flexion gain was correlated to preoperative flexion (r=−0.75, p<0.001). The flexion gain in the RPF group was significantly greater than in the RP group (13+-20 versus 6+-13; p=0.02) as was the ROM gain (10±17° versus 4±12°; p=0.02). However, the one-year active mean flexions were not significantly different (118±14° versus 116±6°; p=0.47). In patients whose preoperative flexion was less than 120° (18 and 27 RPF prostheses), the flexion and ROM gains were significantly greater in the RPF group (23±16° versus 14±16°; p=0.03 and 26±18° versus 17±9°; p=0.05), and the mean one-year active flexion was also greater in the RPF group (124±13° versus 116±8°, p=0.02). In patients with more than 120° of preoperative flexion, the flexion and ROM gains and the final mean flexions in both groups were comparable. In particular, there were nine patients in the RP group and ten patients in the RPF group whose flexion decreased.

Conclusion

Thus, the Sigma RPF prosthesis provided a significant additional flexion gain in patients with 90–120° preoperative flexion, and less than 20° flexion contracture. Patients with a preoperative flexion greater than 120° were exposed to a decrease in flexion range whichever implant was used, RP or RPF.

Level of evidence

Level 3, therapeutic study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total knee arthroplasty (TKA), TKA flexion, Knee osteoarthritis


Mappa


© 2010  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 96 - N° 4

P. 376-380 - giugno 2010 Ritorno al numero
Articolo precedente Articolo precedente
  • Total hip arthroplasty offset measurement: Is C T scan the most accurate option?
  • G. Pasquier, G. Ducharne, E. Sari Ali, F. Giraud, A. Mouttet, E. Durante
| Articolo seguente Articolo seguente
  • Experimental study of tendon healing early phase: Is IGF-1 expression influenced by platelet rich plasma gel?
  • D.N. Lyras, K. Kazakos, G. Agrogiannis, D. Verettas, A. Kokka, G. Kiziridis, E. Chronopoulos, M. Tryfonidis

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.