Abbonarsi

Component positioning in primary total hip replacement: A prospective comparative study of two anterolateral approaches, minimally invasive versus gluteus medius hemimyotomy - 10/02/11

Doi : 10.1016/j.otsr.2010.05.013 
F. Mouilhade a, ⁎ , J. Matsoukis b, P. Oger c, C. Mandereau a, V. Brzakala a, F. Dujardin a
a Academic Department of Orthopedic Surgery and Traumatology, Rouen University Hospital, 1, rue de Germont, 76000 Rouen, France 
b Orthopedic Department, Le Havre Hospital Group, J. Monod Hospital, 29, rue Pierre-Mendès, 76290 Montivilliers, France 
c Orthopedic Department, Mignot Hospital, 177, route de Versailles, 78157 Le Chesnay, France 

Corresponding author. Tel.: +33 0 232880160.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Summary

Introduction

One factor of implant survivorship in total hip replacement (THR) is the quality of implant choice and positioning. The purported advantages of minimally invasive approaches are faster recovery, shorter hospital stay and less per-operative blood loss. On the other hand, there have been many reports of higher complication rates, and doubts as to the quality of implant positioning.

Hypothesis

The quest to minimize tissue damage is at the cost of THR positioning quality.

Objectives

To assess implant positioning in a prospective comparative continuous multicenter series.

Patients and methods

Between 2008 and 2009, a prospective comparative study was conducted on a continuous series of 141 THRs. Ninety-two were performed in two centers, using a minimally invasive Watson-Jones approach; the other 49, performed in a 3rd center, used an anterolateral approach with anterior hemimyotomy. The surgeons were in all cases experienced in their technique. Short-term follow-up comprised clinical and functional (Postel Merle d’Aubigné (PMA), Harris, SF12, WOMAC) and biological assessment (serum creatine phosphokinase (CPK), myoglobinemia, hematocrit) and analysis of complications and of implant positioning on X-ray and CT-scan.

Results

On the Watson-Jones approach, surgery time was longer; day-1 analgesic administration was lower; PMA, Harris and WOMAC scores were better at 6 weeks; and CPK levels were lower at 24 and 48hours. There were no significant differences on the other clinical and biological criteria. Implant positioning analysis revealed significantly greater combined anteversion and greater variation in acetabular inclination mean with the Watson-Jones approach, but no differences in cup positioning, femoral stem positioning, or limb length discrepancy.

Discussion

The minimally invasive Watson-Jones approach provided faster recovery and less muscular damage. However, implant positioning was less precise in terms of acetabular cup inclination.

Level of evidence

Level III. Prospective, comparative, non-randomized.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total hip arthroplasty, Mini-incision, Rottinger, Watson-Jones, Implant positioning


Mappa


© 2010  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 97 - N° 1

P. 14-21 - febbraio 2011 Ritorno al numero
Articolo precedente Articolo precedente
  • Treatment of recurrent THR dislocation using of a cementless dual-mobility cup: A 59 cases series with a mean 8 years’ follow-up
  • F. Leiber-Wackenheim, B. Brunschweiler, M. Ehlinger, A. Gabrion, P. Mertl
| Articolo seguente Articolo seguente
  • Non-simultaneous bilateral hip fracture: Epidemiologic study of 241 hip fractures
  • E. Gaumetou, S. Zilber, P. Hernigou

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.