Abbonarsi

Changes in reference vessel diameter in ST-segment elevation myocardial infarction after primary percutaneous coronary intervention: Implications for appropriate stent sizing - 06/08/11

Doi : 10.1016/j.ahj.2011.04.016 
Ecaterina Cristea, MD a, Gregg W. Stone, MD, FACC a, Roxana Mehran, MD, FACC a, b, Ajay J. Kirtane, MD, FACC a, Sorin J. Brener, MD, FACC c,
a Columbia University Medical Center and the Cardiovascular Research Foundation, New York, NY 
b Mount Sinai Medical Center and the Cardiovascular Research Foundation, New York, NY 
c New York Methodist Hospital and the Cardiovascular Research Foundation, Brooklyn and New York, NY 

Reprint requests: Sorin J. Brener MD, FACC, Cardiac Catheterization Laboratory, NY Methodist Hospital, 506 6th street, KP-2, Brooklyn, NY 11215.

Riassunto

Background

Stents may be undersized during primary percutaneous coronary intervention (PCI) in ST-segment elevation myocardial infarction (STEMI), leading to higher rates of stent thrombosis. We sought to compare the reference vessel diameter (RVD) of the infarct-related artery before, immediately after, and at late follow-up after PCI for STEMI. We further investigated whether vessels treated with paclitaxel-eluting (PES) or bare-metal stents (BMS) behave differently with respect to RVD at follow-up.

Methods

From the HORIZONS-AMI trial, we identified 2,974 patients (3,589 lesions) with complete quantitative angiographic data for stent implantation (2,233 treated with PES and 741 treated with BMS).

Results

Considering all lesions, the median RVD was 2.87 mm (25th-75th percentile 2.54-3.22 mm) at baseline, 2.92 mm (2.58-3.28 mm) immediately post-PCI, and 2.88 mm (2.55-3.22 mm) after 13 months (1,197 patients; P = .001 pre vs post, P = .06 post vs follow-up, and P = .21 pre vs follow-up). There were no significant differences between the RVD for PES versus BMS at any period. The maximal stent or balloon size was 3.00 mm (3.00-3.50 mm) for both groups. There were no differences in RVD at baseline or post-PCI between patients with and without stent thrombosis.

Conclusions

Reference vessel diameter does not change substantially from baseline to follow-up, irrespective of stent type. Stent diameter was appropriate for vessel size. The RVD of patients with and without stent thrombosis was similar at baseline and post-PCI. Thus, the high rates of stent thrombosis after primary PCI for STEMI cannot be attributed to stent undersizing.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2011  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 162 - N° 1

P. 173-177 - luglio 2011 Ritorno al numero
Articolo precedente Articolo precedente
  • Polymorphisms associated with in vitro aspirin resistance are not associated with clinical outcomes in patients with coronary artery disease who report regular aspirin use
  • Deepak Voora, John Horton, Svati H. Shah, Linda K. Shaw, L. Kristin Newby
| Articolo seguente Articolo seguente
  • Association of initial Thrombolysis in Myocardial Infarction flow grade with mortality among patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention: A National Registry of Myocardial Infarction-5 (NRMI-5) analysis
  • Jinhui Wu, Yuri B. Pride, Paul D. Frederick, C. Michael Gibson

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.