Abbonarsi

Clinical Profile, Prognostic Implication, and Response to Treatment of Pulmonary Hypertension in Patients With Severe Aortic Stenosis - 06/08/11

Doi : 10.1016/j.amjcard.2010.11.031 
Itsik Ben-Dor, MD, Steven A. Goldstein, MD, Augusto D. Pichard, MD, Lowell F. Satler, MD, Gabriel Maluenda, MD, Yanlin Li, MD, Asmir I. Syed, MD, Manuel A. Gonzalez, MD, MPH, Michael A. Gaglia, MD, MSc, Kohei Wakabayashi, MD, Cedric Delhaye, MD, Loic Belle, MD, Zuyue Wang, MD, Sara D. Collins, MD, Rebecca Torguson, MPH, Petros Okubagzi, MD, Adefolaseyi Aderotoye, MS, Zhenyi Xue, MS, William O. Suddath, MD, Kenneth M. Kent, MD, PhD, Stephen E. Epstein, MD, Joseph Lindsay, MD, Ron Waksman, MD
Division of Cardiology, Washington Hospital Center, Washington, D.C. 

Corresponding author: Tel: 202-877-2812; fax: 202-877-2715

Riassunto

The incidence, correlates, and prognostic implications of pulmonary hypertension (PH) are unclear in patients with severe aortic stenosis (AS). We studied 509 patients with severe AS evaluated for transcatheter aortic valve implantation (TAVI). Patients were divided into groups based on pulmonary artery systolic pressure (PASP): group I, 161 (31.6%) with PASP <40 mm Hg; group II, 175 (34.3%) with PASP 40 to 59 mm Hg; and group III, 173 (33.9%) with PASP ≥60 mm Hg. Group III patients were more symptomatic and had higher creatinine levels and higher left ventricular end-diastolic pressure. Transpulmonary gradient was >12 mm Hg in 17 patients (10.5%), 31 patients (17.7%), and 80 patients (46.2%) in groups I through III, respectively. In a median follow-up of 202 days (73 to 446) mortality rates were 35 (21.7%), 69 (39.3%), and 85 (49.1%) in groups I through III, respectively (p <0.001). Immediately after TAVI, in patients with PASP >40 mm Hg there was significant decrease in PASP (63.1 ± 16.2 to 48.8 ± 12.4 mm Hg, p <0.0001), which remained at 1 year (50.1 ± 13.1 mm Hg, p = 0.04). After surgical aortic valve replacement there was a significant immediate decrease in PASP (66.1 ± 16.3 to 44.7 ± 14.2 mm Hg, p <0.0001), which persisted at 3 to 12 months (44.8 ± 20.1 mm Hg, p <0.001). In patients who underwent balloon aortic valvuloplasty, PASP decreased immediately after the procedure (63.2 ± 14.8 to 51.8 ± 17.1 mm Hg, p <0.0001), yet at 3 to 12 months pressure returned to baseline levels (57.4 ± 17.0 mm Hg, p = 0.29). In conclusion, patients with severe AS have a high prevalence of PH, and in patients with severe AS increased PASP is associated with increased mortality. Surgical aortic valve replacement and TAVI are effective treatments for these patients and result in a significant PASP decrease.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2011  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 107 - N° 7

P. 1046-1051 - aprile 2011 Ritorno al numero
Articolo precedente Articolo precedente
  • Comparison of Inhaled Nitric Oxide Versus Oxygen on Hemodynamics in Patients With Mitral Stenosis and Severe Pulmonary Hypertension After Mitral Valve Surgery
  • Juliano L. Fernandes, Roney O. Sampaio, Carlos M. Brandão, Tarso Augusto D. Accorsi, Luiz F. Cardoso, Guilherme S. Spina, Flavio Tarasoutchi, Pablo Pomerantzeff, Jose O. Auler, Max Grinberg
| Articolo seguente Articolo seguente
  • Relation of Myocardial Mechanics in Severe Aortic Stenosis to Left Ventricular Ejection Fraction and Response to Aortic Valve Replacement
  • Shemy Carasso, Oved Cohen, Diab Mutlak, Zvi Adler, Jonathan Lessick, Doron Aronson, Shimon A. Reisner, Harry Rakowski, Gil Bolotin, Yoram Agmon

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.