Abbonarsi

Value of the Surface Electrocardiogram in Detecting Right Ventricular Dilatation in the Presence of Left Bundle Branch Block - 06/08/11

Doi : 10.1016/j.amjcard.2010.10.051 
Rutger J. Van Bommel, MD a, Nina Ajmone Marsan, MD a, Victoria Delgado, MD a, Eva P.M. van Rijnsoever, MSc a, Martin J. Schalij, MD, PhD a, Jeroen J. Bax, MD, PhD a, , Hein J. Wellens, MD, PhD b
a Department of Cardiology, Leiden University Medical Center, Leiden, The Netherlands 
b Cardiovascular Research Institute, Maastricht, The Netherlands 

Corresponding author: Tel: 31-71-526-2020; fax: 31-71-526-6809

Riassunto

Approximately 20% of patients with heart failure have left bundle branch block (LBBB) on surface electrocardiogram (ECG). In this group of patients, detection of right ventricular (RV) dilatation on standard ECG can be of clinical relevance because RV enlargement is an important prognostic marker. Consequently, the aim of this study was to evaluate diagnostic accuracy for several electrocardiographic criteria in determining significant RV dilatation in these patients. Standard 12-lead ECGs were obtained in 173 patients with heart failure and known LBBB. From the ECG, 3 criteria for RV dilatation were defined: presence of terminal positivity in lead aVR (late R wave in lead aVR), low voltage (<0.6 mV) in all extremity leads, and an R/S ratio <1 in lead V5. In addition, all patients underwent comprehensive echocardiographic evaluation including assessment of RV dimensions. Measurements were performed blinded to electrocardiographic results. Significant RV dilatation was defined as an RV base-to-apex length ≥86 mm or an RV diastolic area ≥33 cm2. Eighty-six patients (50%) had a late R wave in lead aVR, 36 patients (21%) had low voltage in extremity leads, and 67 patients (39%) had an R/S ratio <1 in lead V5. An RV base-to-apex length ≥86 mm was present in 67 patients (39%), and 62 patients (36%) had an RV diastolic area ≥33 cm2. Any combination of 2 to 3 positive criteria could predict an RV base-to-apex length ≥86 mm with a positive predictive value of 89% and a negative predictive value of 88%. Similarly, an RV diastolic area ≥33 cm2 was predicted with a positive predictive value of 80% and a negative predictive value of 88%. In conclusion, combining 2 to 3 distinct electrocardiographic criteria allows for accurate detection of RV dilatation in patients with heart failure and LBBB.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2011  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 107 - N° 5

P. 736-740 - marzo 2011 Ritorno al numero
Articolo precedente Articolo precedente
  • Effect and Clinical Prediction of Worsening Renal Function in Acute Decompensated Heart Failure
  • Tobias Breidthardt, Thenral Socrates, Markus Noveanu, Theresia Klima, Corinna Heinisch, Tobias Reichlin, Mihael Potocki, Albina Nowak, Christopher Tschung, Nisha Arenja, Roland Bingisser, Christian Mueller
| Articolo seguente Articolo seguente
  • Relation of Aortic Valve Weight to Severity of Aortic Stenosis
  • Renato Razzolini, Susy Longhi, Giuseppe Tarantini, Stefania Rizzo, Massimo Napodano, Elena Abate, Chiara Fraccaro, Gaetano Thiene, Sabino Iliceto, Gino Gerosa, Cristina Basso

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.