Abbonarsi

Quantitative Blush Evaluator accurately quantifies microvascular dysfunction in patients with ST-elevation myocardial infarction: Comparison with cardiovascular magnetic resonance - 09/08/11

Doi : 10.1016/j.ahj.2011.04.014 
Italo Porto, MD, PhD a, , d , Christian Hamilton-Craig, MBBS, FRACP a, c, d, Giovanni Luigi De Maria, MD a, Rocco Vergallo, MD a, Giorgio Cautilli, MD a, Leonarda Galiuto, MD, PhD, FACC a, Francesco Burzotta, MD, PhD a, Antonio Maria Leone, MD, PhD a, Giampaolo Niccoli, MD, PhD a, Luigi Natale, MD b, Lorenzo Bonomo, MD b, Filippo Crea, MD, FESC, FACC a
a Department of Cardiovascular Medicine, Catholic University of the Sacred Heart, Rome, Italy 
b Department of BioImaging, Catholic University of the Sacred Heart, Rome, Italy 
c University of Queensland, Brisbane, Australia 

Reprint requests: Italo Porto, MD, PhD, Department of Cardiovascular Medicine, Catholic University of the Sacred Heart, L.go A. Gemelli, 8-00168 Rome, Italy.

Riassunto

Background

After ST-elevation myocardial infarction (STEMI), microvascular obstruction (MVO) can be assessed using semiquantitative angiographic “blush” scores subject to interoperator variability. Quantitative Blush Evaluator (QuBE) is a free computer-calculated algorithm that evaluates myocardial blush on a continuous scale with improved reproducibility. We aimed to compare QuBE with cardiovascular magnetic resonance (CMR) in detecting MVO and its severity.

Methods

Fifty-two STEMI treated with successful primary percutaneous coronary intervention were enrolled. Quantitative Blush Evaluator and electrocardiographic sum ST-segment resolution were blindly calculated. All patients underwent CMR 4 to 7 days after STEMI for assessment of infarct size (IS), myocardial salvage index, MVO (both as first-pass MVO and delayed-enhancement MVO [DE-MVO]), and presence of intramyocardial hemorrhage on T2-weighted sequences.

Results

Quantitative Blush Evaluator values were inversely related to IS (R = −0.4, P = .008), DE-MVO (R = −0.7, P < .001), and first-pass MVO (R = −0.4, P = .002) and positively related to myocardial salvage index (R = 0.4, P = .007). Moreover, patients with intramyocardial hemorrhage had significantly lower QuBE values (3.9, 3.5-8.0 vs 12.2, 8.2-16.0, P = .001) than those without. At receiver operating characteristic curve analysis, QuBE accounted for an area under the curve of 0.88 (95% CI 0.7-0.9, P = .001) for both DE-MVO and hemorrhage detection and performed significantly better than ST resolution.

Conclusions

Quantitative Blush Evaluator score correlates with IS and microvascular dysfunction by CMR and can be considered as an accurate tool for the assessment of MVO in clinical practice. Quantitative Blush Evaluator is a useful quantitative angiographic technique for the assessment of myocardial reperfusion after STEMI.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2011  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 162 - N° 2

P. 372 - agosto 2011 Ritorno al numero
Articolo precedente Articolo precedente
  • Relationship between clopidogrel-induced platelet P2Y12 inhibition and stent thrombosis or myocardial infarction after percutaneous coronary intervention—A case-control study
  • Christoph Varenhorst, Sasha Koul, David Erlinge, Bo Lagerqvist, Agneta Siegbahn, Lars Wallentin, Stefan James
| Articolo seguente Articolo seguente
  • Clinical characteristics of patients with asymptomatic recurrences of atrial fibrillation in the Gruppo Italiano per lo Studio della Sopravvivenza nell'Infarto Miocardico–Atrial Fibrillation (GISSI-AF) trial
  • Marcello Disertori, Federico Lombardi, Simona Barlera, Aldo Pietro Maggioni, Chiara Favero, Maria Grazia Franzosi, Donata Lucci, Lidia Staszewsky, Gianna Fabbri, Silvia Quintarelli, Leopoldo Bianconi, Roberto Latini

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.