Abbonarsi

Oxygen inhalation using an oxygen concentrator in a low-pressure environment outside of a hospital - 15/08/11

Doi : 10.1016/j.ajem.2007.12.009 
Hirokazu Sakaue, MD, Takashi Suto, MD, Masafumi Kimura, MD, Sou Narahara, MD, Tomonobu Sato, MD, Masaru Tobe, MD, Chizu Aso, MD, Toshie Kakinuma, BA, Makiko Hardy-Yamada, MD, Shigeru Saito, MD
Department of Anesthesiology, Gunma University Graduate School of Medicine, Maebashi 371-8511, Japan 

Corresponding author. Department of Anesthesiology, Gunma University Graduate School of Medicine, Maebashi 371-8511, Japan. Tel.: +81 027 220 8454; fax: +81 027 220 8473.

Abstract

Supplementation with oxygen is fundamental in rescue and emergency medicine. However, transportation of oxygen cylinders or a rigid hyperbaric chamber requires large work forces. Also, oxygen in a cylinder may be completely consumed during a rescue action. The oxygen concentrators, which enrich the oxygen percentage of ambient air, may free rescuers from carrying heavy oxygen cylinders. In the present study, 2 types of oxygen concentrators were tested in a mountain hut located at an altitude of 3776 m. Oxygen concentration of the generated gas was 28.6% ± 0.8% with the first machine, which was powered by an internal battery. Arterial oxygen saturation of the volunteers inhaling through the machine increased from the original 79% ± 6% to 82% ± 6%. When the machine was used with a semi-closed circuit, the value increased further to 90% ± 3%. The second concentrator, which was powered by an external electric generator, outputted 90% ± 2% oxygen. Arterial oxygen saturation of the volunteers increased to 95% ± 1%. It is concluded that both types of oxygen concentrators were efficient at high altitude.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 This work was supported by a grant-in-aid from the Japanese Ministry of Education and Science and by a research grant from Dentsu, Inc. The results of this study were partly presented in 2 local meetings (the 26th Annual Meeting of the Japan Society for Clinical Anesthesia and the 25th Annual Meeting of the Japanese Society of Mountain Medicine). The authors appreciate Mr Kazuhiro Sasaki (Teijin, Inc) and Mr Shaphan Hardy Yamada (English editor) for their contribution to this study.


© 2008  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 26 - N° 9

P. 981-984 - novembre 2008 Ritorno al numero
Articolo precedente Articolo precedente
  • Hyperventilation and finger exercise increase venous-arterial Pco2 and pH differences
  • Akira Umeda, Kazuteru Kawasaki, Tadashi Abe, Maki Watanabe, Akitoshi Ishizaka, Yasumasa Okada
| Articolo seguente Articolo seguente
  • Adverse events associated with ketamine for procedural sedation in adults
  • Reuben J. Strayer, Lewis S. Nelson

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.