Optimizing the Programation of Cardiac Resynchronization Therapy Devices in Patients With Heart Failure and Left Bundle Branch Block - 15/08/11

Doi : 10.1016/j.amjcard.2007.04.046 
Bàrbara Vidal, MD 1, Marta Sitges, MD, PhD ⁎ , Alba Marigliano, MD, Victoria Delgado, MD 1, Ernesto Díaz-Infante, MD, Manel Azqueta, MD, David Tamborero, MSE, José María Tolosana, MD 1, Antonio Berruezo, MD, Félix Pérez-Villa, MD, PhD, Carles Paré, MD, PhD, Lluís Mont, MD, PhD, Josep Brugada, MD, PhD
Thorax Clinic Institute, Hospital Clínic, Institut d’Investigacions Biomèdiques August Pi i Sunyer, University of Barcelona, Barcelona, Spain. 

Corresponding author: Tel: 34-93-227-9305; fax: 34-93-451-41-48.

Riassunto

This study was conducted to investigate the clinical impact of cardiac resynchronization device optimization. A series of 100 consecutive patients received cardiac resynchronization therapy. In the first 49 patients, an empirical atrioventricular delay of 120 ms was set, with simultaneous biventricular stimulation (interventricular [VV] interval = 0 ms). In the next 51 patients, systematic atrioventricular optimization was performed. VV optimization was also performed, selecting 1 VV delay: right or left ventricular preactivation (+30 or −30 ms) or simultaneous (VV interval = 0 ms), according to the best synchrony obtained by tissue Doppler–derived wall displacement. At follow-up, patients who were alive without cardiac transplantation and showed improvement of ≥10% in the distance walked in the 6-minute walking test were considered responders. There were no differences between the 2 groups at baseline. Left ventricular ejection fraction improved in the 2 groups, but left ventricular cardiac output improved only in the optimized group. At 6 months, patients with optimized devices walked slightly further in the 6-minute walking test (497 ± 167 vs 393 ± 123 m, p <0.01), with no differences in New York Heart Association functional class or quality of life compared with nonoptimized patients. Overall, the number of nonresponders were similar in the 2 groups (27% vs 23%, p = NS). In conclusion, the echocardiographic optimization of cardiac resynchronization devices provided a slight incremental clinical benefit at midterm follow-up. Simple and rapid methods to routinely optimize the devices are warranted.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 This study was supported in part by a grant from Fundación Española del Corazón 2006, Madrid, and by Grant FIS PI04/90069 from Fondo de Investigaciones Sanitarias, Madrid, Spain.


© 2007  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 100 - N° 6

P. 1002-1006 - settembre 2007 Ritorno al numero
Articolo precedente Articolo precedente
  • Reliability of Echocardiography for Hemodynamic Assessment of End-Stage Heart Failure
  • Nicolas Mansencal, Laure Revault d’Allonnes, Alain Beauchet, Séverine Fabre, Franck Digne, Jean-Christian Farcot, Thierry Joseph, Olivier Dubourg
| Articolo seguente Articolo seguente
  • Comparison of the Effects of Cardiac Resynchronization Therapy in Patients With Class II Versus Class III and IV Heart Failure (from the InSync/InSync ICD Italian Registry),
  • Maurizio Landolina, Maurizio Lunati, Maurizio Gasparini, Massimo Santini, Luigi Padeletti, Augusto Achilli, Stefano Bianchi, Francesco Laurenzi, Antonio Curnis, Antonio Vincenti, Sergio Valsecchi, Alessandra Denaro, InSync/InSync ICD Italian Registry Investigators

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.