Comparison of Multidetector Computed Tomography and Two-Dimensional Transthoracic Echocardiography for Left Ventricular Assessment in Patients With Heart Failure - 16/08/11

Doi : 10.1016/j.amjcard.2006.08.021 
Javed Butler, MD, MPH a, , Michael D. Shapiro, DO a, Davindar Jassal, MD b, Tomas Neilan, MD b, John Nichols, MD a, Maros Ferencik, MD, PhD a, Thomas J. Brady, MD a, Udo Hoffmann, MD, MPH a, Ricardo C. Cury, MD a
a Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston Massachusetts 
b Division of Cardiology, Massachusetts General Hospital, Harvard Medical School, Boston Massachusetts. 

Corresponding author: Tel: 617-726-5954; fax: 617-724-4152.

Riassunto

Along with coronary evaluation, 64-slice multidetector computed tomography (MDCT) permits comprehensive assessment of left ventricular (LV) anatomy and function; however, how it compares with 2-dimensional transthoracic echocardiography (TTE) in patients with heart failure (HF) is not known. In this study, we compared 25 patients with ejection fractions of <45% who underwent TTE and MDCT. The global ejection fraction by TTE versus MDCT was 36 ± 8% versus 38 ± 12% (r = 0.67, p = NS). The mean LV end-diastolic and end-systolic diameters by TTE and MDCT were 56 ± 8 and 46 ± 9 mm and 58 ± 12 and 47 ± 11 mm, respectively (r = 0.71 and 0.77, respectively, both p >0.20). The mean lateral and septal wall thicknesses by TTE and MDCT were 10 ± 1.4 and 11 ± 1.5 mm and 10 ± 1.3 and 10 ± 1.4 mm (r = 0.77 and 0.76, respectively, both p >0.20). The mean LV end-diastolic and end-systolic volumes and stroke volume by TTE and MDCT were 123 ± 45, 78 ± 31, and 44 ± 21 ml and 140 ± 58, 92 ± 43, and 48 ± 24 ml, respectively (r = 0.62, 0.67, and 0.60, respectively, all p >0.20). The regional wall motion assessment correlation was good between the 2 modalities (κ = 0.61). The interobserver correlation between the 2 MDCT readers ranged from good (r = 0.72 for LV end-diastolic volume) to excellent (r = 0.84 for septal wall thickness). In conclusion, MDCT provides comparable results to TTE for LV structure and functional assessment among patients with HF.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Dr. Brady received a teaching grant from Seimens, Forchhiem, Germany. Drs. Butler, Shapiro, and Ferencik were supported in part by Grant 1-T32-HL076136-02 from the National Institutes of Health, Bethesda, Maryland.


© 2007  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 99 - N° 2

P. 247-249 - gennaio 2007 Ritorno al numero
Articolo precedente Articolo precedente
  • Usefulness of Preimplantation B-Type Natriuretic Peptide Level for Predicting Response to Cardiac Resynchronization Therapy
  • Nicolas Lellouche, Carlos De Diego, David A. Cesario, Marmar Vaseghi, Barbara Natterson Horowitz, Aman Mahajan, Isaac Wiener, Noel G. Boyle, Gregg C. Fonarow, Kalyanam Shivkumar
| Articolo seguente Articolo seguente
  • Relation of β2-Adrenoceptor Haplotype to Risk of Death and Heart Transplantation in Patients With Heart Failure
  • Jaekyu Shin, Maximilian T. Lobmeyer, Yan Gong, Issam Zineh, Taimour Y. Langaee, Hossein Yarandi, Richard S. Schofield, Juan M. Aranda, James A. Hill, Daniel F. Pauly, Julie A. Johnson

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.