Abstract

Background

EUS-guided pancreatic pseudocyst and abscess drainage ideally requires the insertion of both a transmural stent and nasocystic catheter to ensure continuous irrigation and effective drainage. Sequential stent and nasocystic catheter insertion may be time consuming because of the difficulty in recannulating the pseudocyst after the initial stent placement.

Objective

Our purpose was to describe a novel one-step simultaneous double-wire technique that facilitates effective pancreatic pseudocyst and abscess drainage.

Design

To solve the problem of recannulating the pseudocyst cavity after the initial transmural stent placement, we developed a prototype 3-layer puncture kit that allows the simultaneous insertion of 2 guidewires at the initial puncture in one step. This puncture kit consists of a 22-gauge needle used for FNA, a 6F inner polytetrafluoroethylene (Teflon) catheter, and an outer 8.5F Teflon catheter.

Setting

Tertiary referral center.

Patients

Eight consecutive patients were treated.

Interventions

With use of a therapeutic linear echoendoscope and the assembled kit with the needle protruding out distally, the pseudocyst cavity was punctured by using electrocautery. The needle and the inner catheter were then withdrawn, leaving the outer catheter within the cavity. The size of this outer catheter permitted the simultaneous insertion of two 0.035-inch guidewires. Sequential insertion of a transmural stent and nasocystic catheter was then performed without a need for recannulation of the pseudocyst or abscess cavity.

Main Outcome Measurements

Successful endoscopic drainage.

Results

All patients were successfully treated without complications. Mean procedural time was 32.5 minutes (range 25-45 minutes).

Conclusions

With this novel technique, establishing an irrigation system for the treatment of pancreatic pseudocysts and abscesses becomes easier, faster, and safer.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2006  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 64 - N° 5

P. 805-808 - novembre 2006 Ritorno al numero
Articolo precedente Articolo precedente
  • Endoscopic removal of eroded bands in vertical banded gastroplasty: a novel use of endoscopic scissors (with video)
  • John A. Evans, Noel N. Williams, Erick P. Chan, Michael L. Kochman
| Articolo seguente Articolo seguente
  • Pilot study of the porcine uterine horn as an in vivo appendicitis model for development of endoscopic transgastric appendectomy
  • Kazuki Sumiyama, Christopher J. Gostout, Elizabeth Rajan, Timothy A. Bakken, Jodie L. Deters, Mary A. Knipschield, Robert H. Hawes, Anthony N. Kalloo, Pankaj J. Pasricha, Sydney Chung, Sergey V. Kantsevoy, Peter B. Cotton

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.