Abbonarsi

Prospective randomized study comparing coronary artery bypass grafting with the new mini-extracorporeal circulation Jostra System or with a standard cardiopulmonary bypass - 17/08/11

Doi : 10.1016/j.ahj.2005.03.067 
Jean Paul Remadi, MD a, ⁎ , Zava Rakotoarivelo, MD a, Paul Marticho, MD a, Amar Benamar, MD a, b
a Cardiac surgery unit, South Hospital, Amiens Cedex 1, France 
b Anesthesiology unit, South Hospital, Amiens Cedex 1, France 

⁎Reprint requests: J.P. Remadi, MD, Cardiovascular and thoracic surgery unit, South Hospital, 80054 Amiens Cedex 1, France.

Riassunto

Background

To assess the potential benefits of a new concept of cardiopulmonary bypass (CPB), the mini-extracorporeal circulation (MECC) Jostra System, we conducted a prospective randomized study among patients who underwent coronary artery bypass grafting (CABG) with a MECC Jostra System or with a standard CPB.

Methods

In a prospective randomized study, 400 patients underwent elective CABG using a standard CPB (200 patients) or a Jostra MECC System (200 patients). The patients were randomly assigned to have preoperative data similar for both groups.

Results

The operative mortality rate (<30 days) was 1.5% for the MECC group and 2.5% for the CPB group (P = NS). Low-cardiac-output syndrome occurred in 0.66% and 4% for the CPB group (P < .001.). The inflammatory response was significantly reduced with the MECC. Likewise, C-reactive protein release was significantly higher in group B at 24 hours (69.6 ± 38.5 vs 40.8 ± 21.8 mg/L for the group A, P < .01) and at 48 hours (116.7 ± 47.0 vs 65.4 ± 39.5 mg/L, P < .05) postoperatively. In the CPB group, there was a significantly higher decrease of hematocrit and hemoglobin rate. So, the intraoperative transfusion rate amounted to 6% for the MECC group and 12.8% for the CPB group (P < .001). Patients in the CPB group had significantly higher levels of postoperative blood creatinine and urea.

Conclusion

The MECC system is a new concept of CPB that seems to be reliable and safe. To perform CABG, the MECC provides an excellent surgical exposure like a standard CPB and a better biologic profile like CABG without CPB.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2005  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 151 - N° 1

P. 198.e1-198.e7 - gennaio 2006 Ritorno al numero
Articolo precedente Articolo precedente
  • Autologous bone marrow mononuclear cell transplantation in patients undergoing coronary artery bypass grafting
  • David Mocini, Mario Staibano, Luca Mele, Paride Giannantoni, Giacomo Menichella, Furio Colivicchi, Paolo Sordini, Paola Salera, Marco Tubaro, Massimo Santini
| Articolo seguente Articolo seguente
  • Changing trends in the long-term prognosis of patients with acute myocardial infarction: A population-based perspective
  • Naomi F. Botkin, Frederick A. Spencer, Robert J. Goldberg, Darleen Lessard, Jorge Yarzebski, Joel M. Gore

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.