Riassunto

Background

The WATCHMAN left atrial appendage occluder device (Atritech, Inc, Minneapolis, MN) is currently being tested in a Food and Drug Administration–approved clinical trial, the PROTECT AF trial, for patients who are diagnosed with paroxysmal, persistent, or permanent nonvalvular atrial fibrillation. However, rigorous screening and the study design have resulted in the exclusion of a large number of patients. Hence, the purpose of this study was to assess the potential utility of this device among those who were eligible but excluded for trial criteria and the reasons for exclusion.

Methods

Screening logs from the respective sites participating in the PROTECT AF trial were collected and analyzed for potential utilization outside of a research trial. Only 31 patients were enrolled into the research trail from the screening of 1798 total patients.

Results

Information from the excluded patients was examined and it was determined that 79% of these patients would be eligible for the device outside the research trial. Twenty-one percent of patients were not able to receive the device because of long-term warfarin need, contraindications to warfarin, unsuitable anatomy as determined by echocardiography, or the inability to take short-term aspirin and clopidogrel for protocol requirements.

Conclusions

Should a device like the WATCHMAN left atrial appendage occluder be approved, approximately 79% of all patients with atrial fibrillation would be eligible for device placement.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2006  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 152 - N° 4

P. 720-723 - ottobre 2006 Ritorno al numero
Articolo precedente Articolo precedente
  • Survival in octogenarians receiving implantable defibrillators
  • Bruce A. Koplan, Laurence M. Epstein, Christine M. Albert, William G. Stevenson
| Articolo seguente Articolo seguente
  • A history of heart failure predicts arrhythmia treatment efficacy: Data from the Antiarrythmics versus Implantable Defibrillators (AVID) Study
  • Michael A. Brodsky, John McAnulty, Douglas P. Zipes, Christina Baessler, Alfred P. Hallstrom, the AVID Investigators

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.