Abbonarsi

Sputum processing methods to improve the sensitivity of smear microscopy for tuberculosis: a systematic review - 18/08/11

Doi : 10.1016/S1473-3099(06)70602-8 
Karen R Steingart, MD a, b, Vivienne Ng, MPH c, Megan Henry, MPH d, Philip C Hopewell, ProfMD a, b, Andrew Ramsay, MSc e, Jane Cunningham, MD e, Richard Urbanczik, MD f, Mark D Perkins, MD g, Mohamed Abdel Aziz, MD h, Madhukar Pai, DrMD i,
a Division of Pulmonary and Critical Care Medicine, San Francisco General Hospital, University of California, San Francisco, CA, USA 
b Francis J Curry National Tuberculosis Center, San Francisco, CA 
c Albany Medical College, Albany, NY, USA 
d Sacramento County Department of Health and Human Services, Sacramento, CA 
e UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases, World Health Organization, Geneva, Switzerland 
f World Health Organization Tuberculosis Laboratory Consultants Group, Schoemberg, Germany 
g Foundation for Innovative New Diagnostics, Cointrin, Geneva 
h Stop TB Department, World Health Organization, Geneva 
i McGill University, Montreal, Quebec, Canada 

* Correspondence to: Dr Madhukar Pai, Department of Epidemiology, Biostatistics and Occupational Health, McGill University, Montreal, Canada, H3A 1A2

Summary

In low-income and middle-income countries, direct (unconcentrated) sputum smear microscopy is the primary method for diagnosing pulmonary tuberculosis. The method is fast, inexpensive, and specific for Mycobacterium tuberculosis in high incidence areas. The main limitations of direct microscopy are its relatively low sensitivity, especially in individuals co-infected with HIV, and variable quality of the test in programme conditions. Thus, there is a need to identify methods to improve the sensitivity of microscopy. Physical and chemical sputum processing methods, including centrifugation, sedimentation, and bleach, have been studied and found to show promise. We did a systematic review to assess the ability of different processing methods to improve the sensitivity of microscopy. By searching many sources, we identified 83 studies. Overall, by comparison with direct smears, the results suggested that centrifugation with any of several chemical methods (including bleach) is more sensitive, that overnight sedimentation preceded by chemical processing is more sensitive, and that specificity is similar. There were insufficient data to determine the value of sputum processing methods in patients with HIV infection. Operational studies are needed to determine whether the increased sensitivity provided by processing methods is sufficient to offset their increased cost, complexity, and potential biohazards, and to examine their feasibility.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2006  Elsevier Ltd. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 6 - N° 10

P. 664-674 - ottobre 2006 Ritorno al numero
Articolo precedente Articolo precedente
  • Genetic susceptibility to infectious diseases: big is beautiful, but will bigger be even better?
  • David Burgner, Sarra E Jamieson, Jenefer M Blackwell
| Articolo seguente Articolo seguente
  • The polio eradication effort has been a great success—let’s finish it and replace it with something even better
  • Tjeerd G Kimman, Hein Boot

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.