Abbonarsi

Association between cardiac troponin T elevation and angioscopic morphology of culprit lesion in patients with non–ST-segment elevation acute coronary syndrome - 21/08/11

Doi : 10.1016/j.ahj.2004.09.051 
Tomohito Ohtani, MD a, Yasunori Ueda, MD, PhD a, , Masahiko Shimizu, MD a, Isamu Mizote, MD a, Atushi Hirayama, MD, PhD a, Masatsugu Hori, MD, PhD b, Kazuhisa Kodama, MD, PhD a
a Cardiovascular Division, Osaka Police Hospital, Osaka, Japan 
b Division of Cardiology, Department of Internal Medicine and Therapeutics, Osaka University Graduate School of Medicine, Suita, Japan 

Reprint requests: Yasunori Ueda, MD, PhD, Cardiovascular Division, Osaka Police Hospital, 10-31 Kitayama-cho, Tennoji-ku, Osaka 543-0035, Japan.

Riassunto

Background

It is well known that cardiac troponin T (TnT) elevation on admission indicates a high-risk subgroup among patients with non–ST-segment elevation acute coronary syndrome (NSEACS). Although the mechanism of TnT elevation is speculated to be the microthromboembolism from unstable plaques, it has not been clarified. The aim of this study is to clarify the association between the serum TnT elevation and the angioscopically evaluated morphology of culprit lesion in the patients with NSEACS.

Methods

Among 113 patients with NSEACS who had significant coronary stenosis, 62 patients with successful angioscopic examination were prospectively and consecutively enrolled from October 2001 to August 2002. Patients were divided into 2 groups according to the serum TnT level measured before percutaneous coronary intervention: TnT-positive or TnT-negative group. Thrombus and plaque color at culprit lesion were evaluated by angioscopy and were compared between the groups. Plaque color was determined as yellow or white, and thrombus as none, small, or large. Three different definitions for TnT-positive (≥0.1, ≥0.03, and ≥0.01 ng/mL) were used and the sensitivity and specificity for detecting thrombus was compared.

Results

Prevalence of thrombus, large thrombus, and yellow plaque were all higher in TnT-positive than in TnT-negative group for 3 different cutoff values of TnT. Angiographic slow-flow occurred more frequently after percutaneous coronary intervention in TnT-positive than in TnT-negative group for 3 different cutoff values of TnT. Sensitivity/specificity of detecting large thrombus were 33%/100%, 44%/91%, and 56%/83% when TnT-positive was defined as TnT ≥ 0.1, ≥0.03, and ≥0.01 ng/mL, respectively.

Conclusions

Serum TnT level was significantly associated with the prevalence of thrombus and yellow plaque at the culprit lesions of NSEACS. Troponin T, when positive was defined as ≥0.01 ng/mL, still have a high specificity for detecting intracoronary thrombus.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2005  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 150 - N° 2

P. 227-233 - agosto 2005 Ritorno al numero
Articolo precedente Articolo precedente
  • Heart disease epidemic in Pakistan: Women and men at equal risk
  • Tazeen H. Jafar, Fahim H. Jafary, Saleem Jessani, Nish Chaturvedi
| Articolo seguente Articolo seguente
  • Symptoms and type of symptom onset in acute coronary syndrome in relation to ST elevation, sex, age, and a history of diabetes
  • Marie Thuresson, Marianne Berglin Jarlöv, Bertil Lindahl, Leif Svensson, Crister Zedigh, Johan Herlitz

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.