The relationship between electrical axis by 12-lead electrocardiogram and anatomical axis of the heart by cardiac magnetic resonance in healthy subjects - 21/08/11

Doi : 10.1016/j.ahj.2004.10.041 
Henrik Engblom, MD a, John E. Foster, PhD b, Thomas N. Martin, MD b, Bjoern Groenning, MD b, Olle Pahlm, MD, PhD a, Henry J. Dargie, MD, PhD b, Galen S. Wagner, MD c, Håkan Arheden, MD, PhD a, ⁎
a Department of Clinical Physiology, Lund University Hospital, Lund, Sweden 
b Glasgow Cardiac Magnetic Resonance Unit, Glasgow, Lanarkshire, UK 
c Duke University Medical Center, Durham, NC 

⁎Reprint requests: Håkan Arheden, MD, PhD, Department of Clinical Physiology, Lund University Hospital, S-221 85 Lund, Sweden.

Financial support: Swedish Medical Research Council, Swedish Heart Lung Foundation, British Heart Foundation, The Medical Faculty, Lund University.

Riassunto

Background

The traditional assumption has been that there is a close relationship between the electrical and anatomical axes of the heart. The aim of this study was to test the hypothesis that there is a correlation between the electrical and anatomical axes of the heart, in both the frontal and transverse planes, in healthy subjects.

Methods

Ninety-four healthy volunteers (48 men, 46 women; age 21-82 years) were studied by cardiac magnetic resonance and 12-lead electrocardiogram. The anatomical axis was determined by cardiac magnetic resonance and projected onto the frontal and transverse orthogonal planes for comparison with the electrical axis in the corresponding planes.

Results

The electrical and anatomical axes were in the same range in the frontal plane (mean ± SD, +39° ± 31° and +38° ± 10°), but in different ranges in the transverse plane (mean ± SD, −30° ± 18° and +46° ± 7°). The partial correlation coefficients between electrical and anatomical axes were r = 0.30 (P < .01) and r = 0.14 (P = NS) in the frontal and transverse planes, respectively. Age was more strongly correlated to electrical axis than to anatomical axis in the frontal plane.

Conclusions

There is only a weak correlation between electrical and anatomical axes in the frontal plane and no correlation in the transverse plane. The change of electrical axis with increased age is not explained only by change in the anatomical axis. The results suggest that there is no simple relationship between the electrical and anatomical axes of the heart.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2005  Mosby, Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 150 - N° 3

P. 507-512 - settembre 2005 Ritorno al numero
Articolo precedente Articolo precedente
  • Creation of a large-scale genetic data bank for cardiovascular association studies
  • Ramtin Agah, Stephen Ellis, Sue Chase, Mark Henderson, Lisa Mlady, Gurunathan Murugesan, Raymond Tubbs, Kandice Marchant, Ilka Warshawsky, Colleen Rouse, Kathy Hughes, Patricia Welch, Eric J. Topol
| Articolo seguente Articolo seguente
  • The prevalence of bicuspid aortic valve in newborns by echocardiographic screening
  • Ercan Tutar, Filiz Ekici, Semra Atalay, Nazire Nacar

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.