Visual Performance Using a Retinal Prosthesis in Three Subjects With Retinitis Pigmentosa - 21/08/11

Doi : 10.1016/j.ajo.2007.01.027 
Douglas Yanai a, c, James D. Weiland a, Manjunatha Mahadevappa a, Robert J. Greenberg d, Ione Fine b, Mark S. Humayun a,
a Doheny Retina Institute at the Doheny Eye Institute, Keck School of Medicine, University of Southern California, Los Angeles, California 
b Department of Ophthalmology, Zilkha Neurogenetic Institute, Keck School of Medicine, University of Southern California, Los Angeles, California 
c UNIFESP (Federal University of Sao Paulo), Sao Paulo, Brazil 
d Second Sight Medical Products, Inc, Sylmar, California. 

Inquiries to Mark S. Humayun, Doheny Retina Institute at Doheny Eye Institute, University of Southern California, Keck School of Medicine, 1355 San Pablo St. (Room 119), Los Angeles, CA 90033

Riassunto

Purpose

To assess visual task performance in three blind subjects implanted with epiretinal prostheses.

Design

Prospective, investigational device exemption trial.

Methods

Three subjects with light perception or no light perception vision were enrolled at a single center. All subjects had retinitis pigmentosa (RP). Main inclusion criteria: light perception or worse vision in one eye and some visual experience as an adult before blindness. Main exclusion criteria included other ophthalmic problems. A prototype retinal prosthesis was implanted in the eye with worse light sensitivity. The prosthesis had 4 × 4 array of platinum electrodes tacked to the epiretinal surface. The prosthesis was wirelessly controlled by a computer or by a head-worn video camera. Visual function testing was performed in single masked or double masked fashion. Scores from the visual task were compared to chance to determine statistical significance.

Results

The subjects performed significantly better than chance in 83% of the tests. Using the video camera, subjects scored as follows on simple visual tasks: locate and count objects (77% to 100%), differentiate three objects (63% to 73%), determine the orientation of a capital L (50% to 77%), and differentiate four directions of a moving object (40% to 90%). A subset of tests compared camera settings using multipixels vs single pixels. Using multipixel settings, subjects performed better (17%) or equivalent (83%) in accuracy and better (25%) or equivalent (75%) in reaction time.

Conclusions

Three RP implant subjects used epiretinal prostheses to perform simple visual tasks. Multipixel settings proved slightly more effective than single pixel settings.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 Supplemental Material available at AJO.com.


© 2007  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 143 - N° 5

P. 820 - maggio 2007 Ritorno al numero
Articolo precedente Articolo precedente
  • Residual Defect in the Foveal Photoreceptor Layer Detected by Optical Coherence Tomography in Eyes with Spontaneously Closed Macular Holes
  • Esther Privat, Ramin Tadayoni, David Gaucher, Belkacem Haouchine, Pascale Massin, Alain Gaudric
| Articolo seguente Articolo seguente
  • Complications of Primary Placement of Motility Post in Porous Polyethylene Implants During Enucleation
  • Bulent Yazici, Berna Akova, Ozgur Sanli

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.