Single-balloon enteroscopy effectively enables diagnostic and therapeutic retrograde cholangiography in patients with surgically altered anatomy - 22/08/11
Charlottesville, Virginia, USA
Abstract |
Background |
In patients with surgically altered anatomy, ERCP is often unsuccessful. Single-balloon enteroscopy (SBE) enables deep intubation of the small bowel, permitting diagnostic and therapeutic ERCP in this subset of patients.
Objective |
To determine the effectiveness of SBE in performing endoscopic retrograde cholangiography (ERC) in patients with surgically altered anatomy.
Design |
Case series.
Setting |
Large quaternary-care center.
Patients |
Thirteen patients (11 women) underwent 16 SBE procedures with ERCP. Patient anatomy consisted of Whipple (n = 3), hepaticojejunostomy (n = 3), Billroth II (n = 1), and Roux-en-Y (n = 9).
Interventions |
Patients with surgically altered anatomy in whom standard ERCP techniques had failed or were not possible underwent ERC by using SBE with initial therapeutic intent.
Main Outcome Measurements |
Success rates of diagnostic ERC and therapeutic ERC in those patients who required biliary intervention. Procedure-related complications were also assessed.
Results |
Diagnostic ERC was successful 12 (92.3%) of 13 patients and in 13 (81.3%) of 16 cases. Therapeutic ERC was required in 10 patients in whom diagnostic ERC was first accomplished, and therapeutic ERC was successful in 9 (90%) of 10 patients. Biliary interventions included balloon dilation (n = 4), stone extraction (n = 2), sphincterotomy (n = 4), removal of a surgically placed stent (n = 3), and stenting (n = 2). Two patients developed pancreatitis after therapeutic ERC. Median follow-up was 53 days (range 22-522 days). Overall procedural success in an intent-to-treat analysis by case was 75%.
Limitation |
Single-center experience.
Conclusion |
SBE enables diagnostic and therapeutic ERC in most patients with altered anatomy. SBE-assisted therapeutic ERC may be associated with an increased risk of pancreatitis. Improvement of the available equipment is necessary to perform more efficient and effective biliary interventions.
Il testo completo di questo articolo è disponibile in PDF.Abbreviations : DBE, ERC, HJ, LDLT, OLT, PTC, RYGB, SBE
Mappa
| DISCLOSURE: The following authors disclosed financial relationships relevant to this publication: V. M. Shami: Consultant for Olympus. M. Kahaleh: Grant support fromOlympus, Boston Scientific, Alveolus, ConMed, Cook Medical. All other authors disclosed no financial relationships relevant to this publication. |
Vol 71 - N° 3
P. 641-649 - marzo 2010 Ritorno al numeroBenvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.
Già abbonato a @@106933@@ rivista ?