Abbonarsi

Optic Disk and Nerve Fiber Layer Imaging to Detect Glaucoma - 22/08/11

Doi : 10.1016/j.ajo.2007.07.010 
Federico Badalà, Kouros Nouri-Mahdavi, Duna A. Raoof, Narakorn Leeprechanon, Simon K. Law, Joseph Caprioli
Glaucoma Division, Jules Stein Eye Institute, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, California. 

Inquiries to Joseph Caprioli, Glaucoma Division, Jules Stein Eye Institute, 100 Stein Plaza, Los Angeles, CA 90095

Riassunto

Purpose

To compare optic disk and retinal nerve fiber layer (RNFL) imaging methods to discriminate eyes with early glaucoma from normal eyes.

Design

Retrospective, cross-sectional study.

Methods

In a tertiary care academic glaucoma center, 92 eyes of 92 subjects (46 with early perimetric open-angle glaucoma and 46 controls) were studied. Diagnostic performance of optical coherence tomography (StratusOCT; Carl Zeiss Meditec, Dublin, California, USA), scanning laser polarimetry (GDx VCC; Laser Diagnostic Technologies, San Diego, California, USA), confocal laser ophthalmoscopy (Heidelberg Retinal Tomograph [HRT] III; Heidelberg Engineering GmbH, Heidelberg, Germany), and qualitative assessment of stereoscopic optic disk photographs were compared. Outcome measures were areas under receiver operator characteristic curves (AUCs) and sensitivities at fixed specificities. Classification and regression tree (CART) analysis was used to evaluate combinations of quantitative parameters.

Results

The average (± standard deviation) visual field mean deviation for glaucomatous eyes was −4.0 ± 2.5 dB (decibels). Parameters with largest AUCs (± standard error) were: average RNFL thickness for StratusOCT (0.96 ± 0.02), nerve fiber indicator for GDx VCC (0.92 ± 0.03), Frederick S. Mikelberg (FSM) discriminant function for HRT III (0.91 ± 0.03), and 0.97 ± 0.02 for disk photograph evaluation. At 95% specificity, sensitivity of disk photograph evaluation (90%) was greater than GDx VCC (P = .05) and HRT III (P = .002) results, but not significantly different than those of StratusOCT (P > .05). The combination of StratusOCT average RNFL thickness and HRT III cup-to-disk area with CART produced a sensitivity of 91% and specificity of 96%.

Conclusions

StratusOCT, GDx VCC, and HRT III performed as well as, but not better than, qualitative evaluation of optic disk stereophotographs for detection of early perimetric glaucoma. The combination of StratusOCT average RNFL thickness and HRT III cup-to-disk area ratio provided a high diagnostic precision.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2007  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 144 - N° 5

P. 724-732 - novembre 2007 Ritorno al numero
Articolo precedente Articolo precedente
  • Phacoemulsification of Cataract in Patients Receiving Coumadin Therapy: Ocular and Hematologic Risk Assessment
  • Irina S. Barequet, Dan Sachs, Ayelet Priel, Yael Wasserzug, Uri Martinowitz, Joseph Moisseiev, Ophira Salomon
| Articolo seguente Articolo seguente
  • Retinal Sensitivity and Retinal Nerve Fiber Layer Thickness Measured by Optical Coherence Tomography in Glaucoma
  • Stefano Miglior, Ivano Riva, Magda Guareschi, Federico Di Matteo, Filippo Romanazzi, Laura Buffagni, Eliana Rulli

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.