Abbonarsi

A motor-driven single-use colonoscope controlled with a hand-held device: a feasibility study in volunteers - 23/08/11

Doi : 10.1016/j.gie.2007.10.065 
Thomas Rösch, MD , Andreas Adler, MD, Heiko Pohl, MD, Elke Wettschureck, MD, Martin Koch, MD, Bertram Wiedenmann, MD, Nicolas Hoepffner, MD
Current affiliations: Central Interdisciplinary Endoscopy Unit, Department of Gastroenterology, Campus Virchow Hospital (T.R., A.A., H.P., E.W., B.W.), Department of Pathology, Campus Mitte Hospital (M.K.), Charité University Hospitals, Berlin, Germany, Department of Gastroenterology, Frankfurt University Hospital (N.H.), Frankfurt, Germany 

Reprint requests: Thomas Rösch, MD, Central Interdisciplinary Endoscopy Unit, Department of Gastroenterology, Hepatology, and Metabolic Diseases, Charité Medical University of Berlin, Campus Virchow Clinic, Augustenburger Platz 1, 13353 Berlin, Germany.

Berlin, Frankfurt, Germany

Abstract

Background

Several new instruments have been developed in the effort to improve the acceptance of colonoscopy for colorectal cancer screening. A new colonoscope, the Invendoscope, is presented here. It consists of an endoscopic sheath with an inverted sleeve, instrument channel, and an electrohydraulic deflecting tip. The instrument is steered by a hand-held device and propelled by a motorized drive unit.

Objective

Our purpose was to evaluate the feasibility of the new Invendoscope SC40.

Design

Prospective single-arm pilot study over 2 time periods using 2 different instrument prototypes (170 and 180/200 cm).

Patients

Thirty-four healthy volunteers (19 men, mean age 49.7 years). Technical instrument defects led to premature termination in 5 additional volunteers during the 2 study periods (4 in phase 1, 1 in phase 2), who were excluded from further analysis.

Interventions

Total colonoscopy was attempted, with all procedures being performed without sedation.

Main Outcome Measurements

Cecal intubation rate.

Results

The cecum was reached in 82% of the 34 cases (95% CI, 66%-92%), with better results in period 2 than in period 1 (90% vs 79%); of the 6 incomplete examinations, 4 reached the mid transverse colon or beyond and 2 were stopped in the sigmoid colon because of pain. The volunteer rating showed a mean score of 1.96 (range 1-6; 1 = no discomfort). No complications were encountered.

Limitations

No data regarding diagnostic accuracy and no data comparing the instrument with conventional colonoscopy are available as yet.

Conclusions

This pilot proof-of-principle study of a new motor-driven colonoscope showed promising cecal intubation rates and an absence of pain in 92% of cases. Further clinical and comparative studies are warranted.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2008  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 67 - N° 7

P. 1139-1146 - giugno 2008 Ritorno al numero
Articolo precedente Articolo precedente
  • Endoscopic removal of bile-duct stones by using a rotatable papillotome and a large-balloon dilator in patients with a Billroth II gastrectomy (with video)
  • Gwang Ha Kim, Dae Hwan Kang, Geun Am Song, Jeong Heo, Chan Ho Park, Tae In Ha, Kyung Yeob Kim, Hye Jeong Lee, Il Doo Kim, Seong Ho Choi, Chul Soo Song
| Articolo seguente Articolo seguente
  • EUS-guided submucosal implantation of a radiopaque marker: a simple and effective procedure to facilitate subsequent surgical and radiation therapy
  • Priscilla Magno, Samuel A. Giday, Kathleen L. Gabrielson, Eun Ji Shin, John O. Clarke, Chung-Wang Ko, Jonathan M. Buscaglia, Sanjay B. Jagannath, Marcia I. Canto, Sergey V. Kantsevoy

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.