Abbonarsi

The Boston bowel preparation scale: a valid and reliable instrument for colonoscopy-oriented research - 23/08/11

Doi : 10.1016/j.gie.2008.05.057 
Edwin J. Lai, MD, Audrey H. Calderwood, MD, Gheorghe Doros, PhD, Oren K. Fix, MD, MSc, Brian C. Jacobson, MD, MPH, FASGE
Current affiliations: Section of Gastroenterology, Boston University Medical Center (E.J.L., A.H.C., B.C.J.), the Department of Biostatistics, Boston University School of Public Health (G.D.), Boston, Massachusetts, the Division of Gastroenterology, University of Washington (O.K.F.), Seattle, Washington, USA 

Reprint requests: Brian C. Jacobson, MD, Section of Gastroenterology, Boston University Medical Center, 85 East Concord St, Rm 7721, Boston, MA 02118.

Boston, Massachusetts, USA

Abstract

Background

Few bowel-preparation rating scales have been validated. Most scales were intended for comparing oral purgatives and fail to account for washing and/or suctioning by the endoscopist. This limits their utility in studies of colonoscopy outcomes, such as polyp-detection rates.

Objective

To develop a valid and reliable scale for use in colonoscopy outcomes research.

Setting

Academic medical center.

Methods

We developed the Boston bowel preparation scale (BBPS), a 10-point scale that assesses bowel preparation after all cleansing maneuvers are completed by the endoscopist. We assessed interobserver and intraobserver reliability by using video footage of colonoscopies viewed on 2 separate occasions by 22 clinicians. We then applied the BBPS prospectively during screening colonoscopies and compared BBPS scores with clinically meaningful outcomes, including polyp-detection rates and procedure times.

Results

The intraclass correlation coefficient (a measure of interobserver reliability) for BBPS scores was 0.74. The weighted kappa (a measure of intraobserver reliability) for scores was 0.77 (95% CI, 0.66-0.87). During 633 screening colonoscopies, the mean (SD) BBPS score was 6.0 ± 1.6. Higher BBPS scores (≥5 vs <5) were associated with a higher polyp-detection rate (40% vs 24%, P < .02). BBPS scores were inversely correlated with colonoscope insertion (r = –0.16, P < .003) and withdrawal (r = –0.23, P < .001) times.

Limitations

Single-center study.

Conclusions

The BBPS is a valid and reliable measure of bowel preparation. It may be well suited to colonoscopy outcomes research because it reflects the colon’s cleanliness during the inspection phase of the procedure.

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : ASGE, BBPS, DVD, ICC


Mappa


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication. The study was supported by an ASGE/TAP Endoscopic Research Award (B.C.J.) and National Institutes of Health, National Institute of Diabetes and Digestive and Kidney Diseases award K08-DK070706 (B.C.J.).
 Presented at Digestive Disease Week, May 20-23, 2007, Washington, DC (Gastrointest Endosc 2007;65:AB361).
 If you want to chat with an author of this article, you may contact him at brian.jacobson@bmc.org.


© 2009  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 69 - N° 3P2

P. 620-625 - marzo 2009 Ritorno al numero
Articolo precedente Articolo precedente
  • Where the dragon truly sleeps
  • John I. Allen
| Articolo seguente Articolo seguente
  • The outcome of a second preparation for colonoscopy after preparation failure in the first procedure
  • Shomron Ben-Horin, Simon Bar-Meir, Benjamin Avidan

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.