Abbonarsi

Evaluation and validation of computed virtual chromoendoscopy in early gastric cancer - 23/08/11

Doi : 10.1016/j.gie.2008.08.032 
Ritsuo Mouri, MD, Shigeto Yoshida, MD, PhD , Shinji Tanaka, MD, PhD, Shiro Oka, MD, PhD, Masaharu Yoshihara, MD, PhD, Kazuaki Chayama, MD, PhD
Current affiliations: Programs for Biomedical Research (R.M., K.C.), Division of Frontier Medical Science, Department of Medicine and Molecular Science, Graduate School of Biomedical Sciences, Department of Endoscopy (S.Y., S.T., S.O.), Hiroshima University Hospital, Department of Health Service Center (M.Y.), Hiroshima University, Hiroshima, Japan 

Reprint request: Shigeto Yoshida, MD, Department of Endoscopy, Hiroshima University Hospital, 1-2-3 Kasumi, Minami-ku, Hiroshima 734-8551, Japan.

Hiroshima, Japan

Abstract

Background

The Flexible spectral Imaging Color Enhancement (FICE) system estimates the spectrum reflectance from a white-light endoscopic image and reconstitutes a color image from the wavelength, including useful information about the GI tract. The aim of this study was to investigate the usefulness of FICE with a specific wavelength in the assessment of early gastric cancers (EGCs), and the relationship between the FICE visualization and blood vessels.

Design

A retrospective study.

Setting

Department of Endoscopy, Hiroshima University, Hiroshima, Japan.

Patients and Main Outcome Measurements

The study subjects consisted of 100 patients with EGCs (78 differentiated, 22 undifferentiated) who underwent an endoscopic or surgical resection. We analyzed the wavelengths to generate the maximum difference of the spectral reflectance between the normal gastric mucosa and the EGCs. We observed the same visual field first with white-light endoscopy and then with the FICE system. Then, we scored the demarcation of color between the cancer and the normal mucosa of white-light endoscopic observation and FICE observation, each without magnification. We examined the relationship between the score of the FICE image and the section of the vascular space.

Results

The wavelength that generated the maximum difference in the tissue was 530 nm. The score of the FICE observation improved in 46 cases (46%), was unchanged in 54 cases (54%), and decreased in no cases (0%). There was a correlation between the score of the FICE images and the section of the vascular spaces.

Conclusions

The FICE observation demonstrated that setting the wavelength at 530 nm resulted in an improvement in the visualization of the EGCs. It is thought that the FICE system is noninvasive and may more easily detect EGC without dye during both routine and detailed examinations.

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : B, EGC, FICE, G, R


Mappa


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.


© 2009  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 69 - N° 6

P. 1052-1058 - maggio 2009 Ritorno al numero
Articolo precedente Articolo precedente
  • The additional value of EUS-guided Tru-cut biopsy to EUS-guided FNA in patients with mediastinal lesions
  • Lieke P.V. Berger, Robert C.H. Scheffer, Bas L.A.M. Weusten, Cees A. Seldenrijk, Peter C. de Bruin, Robin Timmer, Mark F.J. Stolk
| Articolo seguente Articolo seguente
  • Efficacy and safety of the new WallFlex enteral stent in palliative treatment of malignant gastric outlet obstruction (DUOFLEX study): a prospective multicenter study
  • Jeanin E. van Hooft, Madeleen J. Uitdehaag, Marco J. Bruno, Robin Timmer, Peter D. Siersema, Marcel G.W. Dijkgraaf, Paul Fockens

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.