Abbonarsi

A prospective, randomized, comparative trial evaluating respiratory depression during patient-controlled versus anesthesiologist-administered propofol-remifentanil sedation for elective colonoscopy - 24/08/11

Doi : 10.1016/j.gie.2010.01.031 
Jeff E. Mandel, MD, MS , Gary R. Lichtenstein, MD, David C. Metz, MD, Gregory G. Ginsberg, MD, Michael L. Kochman, MD
Current affiliations: University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania, USA 

Reprint requests: Jeff E. Mandel, MD, MS, Department of Anesthesiology & Critical Care, 780 B Dulles Building, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104.

Riassunto

Background

Patient-controlled sedation (PCS) with propofol-remifentanil (PR) is associated with rapid sedation and recovery, but it is associated with a greater requirement for airway rescue than PCS with midazolam-fentanyl.

Objective

To demonstrate that respiratory depression associated with PR is more frequent during anesthesiologist-administered sedation (AAS) than during PCS.

Design

Prospective, randomized, open-label study.

Setting

Academic medical center.

Patients

Fifty patients undergoing elective colonoscopy.

Intervention

PCS or AAS using PR. All patients breathed 100% oxygen via an anesthesia mask with continuous spirometry and bispectral index (BIS).

Main Outcome Measurements

Respiratory rate and BIS.

Results

Colonoscopy was completed in all patients. No patient under PCS required airway rescue. Five patients under AAS required bag-mask ventilation to resolve Sao2 (arterial oxygen saturation) less than 90% lasting longer than 30 seconds. The median BIS for the AAS group was 71.7 (range 61.06-82.34) and 88.1 (range 83.15-93.05) for the PCS group. Median respiratory rates were 5.97 (range 1.21–10.73) breaths per minute for AAS and 13.19 (range 9.54–16.84) for PCS. Respiratory rates less than 2 breaths per minute composed 28% of the procedure time for AAS, but only 5% for PCS. Patients under PCS had lower median predicted effect site concentrations for PR, but were able to achieve brief peak levels exceeding those with AAS. These differences were significant (P < .001).

Limitations

Potential for bias with AAS.

Conclusions

Patients undergoing colonoscopy with PR are significantly more likely to require intervention for hypoventilation compared with PCS. (Clinical trial registration number:NCT00868920.)

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : AAS, BIS, PCS, PMS, PR


Mappa


 DISCLOSURE: The following authors disclosed financial relationships relevant to this publication: J.E. Mandel: Speaker for Bioniche Pharma. G.R. Lichtenstein: Advisory committee and lecture funding: Consultant: Abbott Laboratories. M.L. Kochman: Spouse: stock and executive: Merck.


© 2010  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 72 - N° 1

P. 112-117 - luglio 2010 Ritorno al numero
Articolo precedente Articolo precedente
  • Achieving complete small-bowel capsule endoscopy: is it possible and does it matter?
  • Felice Schnoll-Sussman
| Articolo seguente Articolo seguente
  • Meshed capillary vessels found on narrow-band imaging without optical magnification effectively identifies colorectal neoplasia: a North American validation of the Japanese experience
  • Zachary H. Henry, Paul Yeaton, Vanessa M. Shami, Michel Kahaleh, James T. Patrie, Dawn G. Cox, David A. Peura, Fabian Emura, Andrew Y. Wang

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.