Abbonarsi

Efficacy of a prototype endoscope with two deflecting working channels for endoscopic submucosal dissection: a prospective, comparative, ex vivo study - 24/08/11

Doi : 10.1016/j.gie.2010.01.056 
Suck-Ho Lee, MD, PhD, Mark A. Gromski, BA, Alexandre Derevianko, MD, Daniel B. Jones, MD, MS, Douglas K. Pleskow, MD, Mandeep Sawhney, MD, Ram Chuttani, MD, Kai Matthes, MD, PhD
Current affiliations: Department of Gastroenterology (S.-H.L., M.A.G., D.K.P., M.S., R.C., K.M.), Shapiro Simulation and Skills Center (A.D.), Department of Surgery, Division of Minimally Invasive Surgery (D.B.J.), Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts, USA 

Reprint requests: Kai Matthes, MD, PhD, Department of Gastroenterology, Beth Israel Deaconess Medical Center, 330 Brookline Avenue, Stoneman 4, Boston, MA 02215

Riassunto

Background

Optimizing the visualization of the cutting line of the submucosal layer is essential to performing an effective and safe endoscopic submucosal dissection (ESD).

Objective

To evaluate the prototype R-scope compared with a conventional, double-channel endoscope in time required for ESD of mucosal lesions in distinct anatomical locations of the stomach.

Design

A prospective, comparative, ex vivo study.

Intervention

ESD.

Main Outcome Measurements

Procedure time (primary end point measure), specimen size, submucosal injection frequency, en bloc resection rate, and perforation rate (secondary end point measures).

Results

In the subgroup of resections in the greater and lesser curvature, the mean (± SD) procedure time was significantly less in the R-scope group compared with the conventional endoscope group (8.4 ± 2.1 minutes vs 11.3 ± 2.1 minutes, respectively; P = .006), and the mean (± SD) submucosal injection frequency was significantly less in the R-scope group compared with the conventional endoscope group (1.9 ± 0.6 vs 2.5 ± 0.5, respectively; P = .025). There were no significant differences in procedure time, specimen size, submucosal injection requirements, en bloc resection rate, and perforation rate between the two endoscopic groups of all combined anatomic lesions.

Limitations

Small, ex vivo study.

Conclusion

ESD by using the R-scope may provide an improved platform for quicker ESD, especially in greater and lesser curvature anatomical lesions of the stomach.

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : EMR, ESD, NOTES


Mappa


 DISCLOSURE: K. Matthes disclosed that he is the chief executive officer of Endosim, LLC. All other authors disclosed no financial relationships relevant to this publication. Grants for material support were received from Endosim (S.-H.L.) and Olympus America (K.M.).


© 2010  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 72 - N° 1

P. 155-160 - luglio 2010 Ritorno al numero
Articolo precedente Articolo precedente
  • Efficacy and safety of single-session argon plasma coagulation in the management of chronic radiation proctitis
  • Michael P. Swan, Greg T.C. Moore, William Sievert, David A. Devonshire
| Articolo seguente Articolo seguente
  • Carbon dioxide versus room air for natural orifice transluminal endoscopic surgery (NOTES) and comparison with standard laparoscopic pneumoperitoneum
  • Stefan von Delius, Johanna Sager, Hubertus Feussner, Dirk Wilhelm, Phillip Thies, Wolfgang Huber, Tibor Schuster, Armin Schneider, Roland M. Schmid, Alexander Meining

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.